DSD Information System
Home >> Toyota >> 2021 >> Highlander LE, 4WD >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heating / Air Conditioning System (Except HV, W/ Auto A/C) - Diagnostics - Introduction >> AIR CONDITIONING SYSTEM (for Gasoline Model with Automatic Air Conditioning System) >> Utility [11/2023 - ] >> Utility [11/2023 - ]

Utility [11/2023 - ]

  1. REFRIGERANT SHORTAGE CHECK USING GTS 
    1. Prepare the vehicle according to the table below.
      MEASUREMENT CONDITION:

      Item Condition
      Vehicle Condition Ignition switch ON (Engine running)
      A/C Switch On
      Ambient Temperature*1 0 to 49°C (32 to 120°F)
      Air Conditioning Air Inlet Temperature*2 25 to 35°C (77 to 95°F)
      Set Temperature MAX COLD
      Recirculation/fresh Control Switch Recirculation
      Air Vent Damper Position FACE
      Blower Speed HI

      HINT: 

      *1: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.

      *2: This inspection can be judged correctly only if the air inlet temperature is within a range of 25 to 35°C (77 to 95°F). Therefore, postpone the test if the temperature is out of range.

    2. Using the GTS, check the amount of refrigerant.

      Body Electrical > Air Conditioner > Utility 

      Tester Display
      Refrigerant Gas Volume Check
      NOTE:

      If the conditions for the inspection are not met, "Refrigerant incorrect" will be displayed on the GTS. Confirm the conditions of the inspection and perform the check again.

      HINT: 

      • If the amount of refrigerant is insufficient, "Refrigerant shortage" is displayed on the GTS and the indicator light on the A/C switch turns off.
      • When performing this inspection, a DTC will not be output even if "Refrigerant shortage" is displayed on the GTS.
      RESULT:

      Result Amount of Refrigerant Corrective Action
      Refrigerant shortage Insufficient
      1. Check for refrigerant leaks using a gas leak detector, and repair if necessary.
      2. Evacuate the air conditioning system and charge it with the appropriate volume of new or purified refrigerant.

        Refer to REPLACEMENT [12/2019 - ]

      Refrigerant correct Correct -
      Refrigerant incorrect Incorrect Confirm the conditions of the inspection and perform the check again.
  2. REFRIGERANT PRESSURE HISTORY CLEAR 
    1. Press the A/C OFF switch.
    2. According to the GTS display, perform refrigerant pressure history clear.

      Body Electrical > Air Conditioner > Utility 

      Tester Display
      Refrigerant Pressure History Clear
  3. A/C OPERATION LIMIT HISTORY COUNT CLEAR 
    1. Press the A/C OFF switch.
    2. According to the GTS display, perform A/C operation limit history count clear.

      Body Electrical > Air Conditioner > Utility 

      Tester Display
      A/C Operation Limit History Count Clear
  4. MY SETTINGS INITIALIZATION 
    1. Press the A/C OFF switch.
    2. According to the GTS display, perform My Settings initialization.

      Body Electrical > Air Conditioner > Utility 

      Tester Display
      My Settings Initialization