DSD Information System
Home >> Toyota >> 2021 >> Highlander LE, 4WD >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heating / Air Conditioning System (Except HV, W/ Auto A/C) - Diagnostic Codes (2 Of 2) >> AIR CONDITIONING SYSTEM (for Gasoline Model with Automatic Air Conditioning System) >> DTC P0070-11: Ambient Temperature Sensor Circuit Short to Ground [11/2023 - ] >> Procedure

DTC P0070-11: Ambient Temperature Sensor Circuit Short to Ground [11/2023 - ]: Procedure

  1. CLEAR DTC 
    1. Clear the DTCs.

      Body Electrical > Air Conditioner > Clear DTCs 

      Result

      Proceed to
      NEXT

    Result: 

    NEXT 

    See step  2

  2. CHECK FOR DTC 

    Pre-procedure1

    1. Turn the ignition switch off.
    2. Disconnect the ambient temp. sensor (cooler thermistor) connector.
      GTY1235899Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *1 Ambient Temp. Sensor (Cooler Thermistor)
      *2 Air Conditioning Amplifier Assembly
    3. Turn the ignition switch to ON and wait for 4 seconds or more.

      Procedure1

    4. Check for DTCs.

      Body Electrical > Air Conditioner > Trouble Codes 

      Result

      Result Proceed to
      P0070-15 is output A
      P0070-11 is output B

      Post-procedure1

    5. None

    Result: 

    REPLACE AMBIENT TEMP. SENSOR (COOLER THERMISTOR) 

    Refer to REMOVAL [11/2023 - ]

    Result: 

    See step  3

  3. CHECK HARNESS AND CONNECTOR (AMBIENT TEMP. SENSOR (COOLER THERMISTOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY) 

    Pre-procedure1

    1. Disconnect the A23 ambient temp. sensor (cooler thermistor) connector.
    2. Disconnect the H63 air conditioning amplifier assembly connector.

      Procedure1

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      A23-2 or H63-1 (TAM) - Other terminals and body ground Always 10 kΩ or higher
      A23-1 or H63-14 (SG-2) - Other terminals and body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

      Post-procedure1

    4. None

    Result: 

    OK 

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY 

    Refer to REMOVAL [11/2023 - ]

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR