DTC P0070-11: Ambient Temperature Sensor Circuit Short to Ground [11/2023 - ]: Procedure
- CLEAR DTC
Result:
NEXT
See step 2
- CHECK FOR DTC
Pre-procedure1
- Turn the ignition switch off.
- Disconnect the ambient temp. sensor (cooler thermistor) connector.
*1 Ambient Temp. Sensor (Cooler Thermistor) *2 Air Conditioning Amplifier Assembly - Turn the ignition switch to ON and wait for 4 seconds or more.
Procedure1
- Check for DTCs.
Body Electrical > Air Conditioner > Trouble Codes
Result
Result Proceed to P0070-15 is output A P0070-11 is output B Post-procedure1
- None
Result:
A
REPLACE AMBIENT TEMP. SENSOR (COOLER THERMISTOR)
Refer to REMOVAL [11/2023 - ]
Result:
B
See step 3
- CHECK HARNESS AND CONNECTOR (AMBIENT TEMP. SENSOR (COOLER THERMISTOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Pre-procedure1
- Disconnect the A23 ambient temp. sensor (cooler thermistor) connector.
- Disconnect the H63 air conditioning amplifier assembly connector.
Procedure1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A23-2 or H63-1 (TAM) - Other terminals and body ground Always 10 kΩ or higher A23-1 or H63-14 (SG-2) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG Post-procedure1
- None
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY
Refer to REMOVAL [11/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR