DTC P0070-15: Ambient Temperature Sensor Circuit Short to Battery or Open [11/2023 - ]: Procedure
- CHECK AMBIENT TEMP. SENSOR (COOLER THERMISTOR) CIRCUIT
Pre-procedure1
- Disconnect the A23 ambient temp. sensor (cooler thermistor) connector.
*a Front view of wire harness connector
(to Ambient Temp. Sensor (Cooler Thermistor))Procedure1
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition A23-2 - Body ground Ignition switch ON 0 to 5.5 V Result
Proceed to OK NG Post-procedure1
- None
Result:
NG
See step 5
Result:
OK
See step 2
- Disconnect the A23 ambient temp. sensor (cooler thermistor) connector.
- CLEAR DTC
Result:
NEXT
See step 3
- CHECK FOR DTC
Pre-procedure1
- Turn the ignition switch off.
- Disconnect the A23 ambient temp. sensor (cooler thermistor) connector.
*a Front view of wire harness connector
(to Ambient Temp. Sensor (Cooler Thermistor)) - Connect terminals 1 and 2 of the ambient temp. sensor (cooler thermistor) connector on the wire harness side.
*1 Ambient Temp. Sensor (Cooler Thermistor) *2 Air Conditioning Amplifier Assembly - Turn the ignition switch to ON and wait for 4 seconds or more.
Procedure1
- Check for DTCs.
Body Electrical > Air Conditioner > Trouble Codes
Result
Result Proceed to P0070-11 is output A P0070-15 is output B Post-procedure1
- None
Result:
A
REPLACE AMBIENT TEMP. SENSOR (COOLER THERMISTOR)
Refer to REMOVAL [11/2023 - ]
Result:
B
See step 4
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AMBIENT TEMP. SENSOR (COOLER THERMISTOR))
Pre-procedure1
- Disconnect the A23 ambient temp. sensor (cooler thermistor) connector.
- Disconnect the H63 air conditioning amplifier assembly connector.
Procedure1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A23-2 - H63-1 (TAM) Always Below 1 Ω A23-1 - H63-14 (SG-2) Always Below 1 Ω Result
Proceed to OK NG Post-procedure1
- None
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY
Refer to REMOVAL [11/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AMBIENT TEMP. SENSOR (COOLER THERMISTOR))
Pre-procedure1
- Disconnect the A23 ambient temp. sensor (cooler thermistor) connector.
- Disconnect the H63 air conditioning amplifier assembly connector.
Procedure1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A23-2 or H63-1 (TAM) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG Post-procedure1
- None
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY
Refer to REMOVAL [11/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR