DTC P06A0-14: Compressor Solenoid Circuit Short to Ground or Open [11/2023 - ]: Procedure
- READ VALUE USING GTS
- Read the Data List according to the display on the GTS.
Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Solenoid Valve Control Current Value Solenoid valve control current Min.: 0 mA
Max.: 1000 mAValue changes between 0 A and 0.997 A in accordance with solenoid valve operation - Body Electrical > Air Conditioner > Data List
Tester Display Solenoid Valve Control Current Value OK
The display is as specified in the normal condition column.
Result
Proceed to OK NG
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [11/2023 - ]
Result:
NG
See step 2
- Read the Data List according to the display on the GTS.
- INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY
Pre-procedure1
- Disconnect the C59 compressor with pulley assembly connector.
Procedure1
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Compressor with Pulley Assembly)Standard Resistance
Tester Connection Condition Specified Condition 1 (SOL-) - 2 (SOL+) Compressor temperature 25°C (77°F) 10.1 to 11.1 Ω Result
Proceed to OK NG Post-procedure1
- None
Result:
NG
REPLACE COMPRESSOR WITH PULLEY ASSEMBLY. Refer to REMOVAL [11/2023 - ]
Result:
OK
See step 3
- Disconnect the C59 compressor with pulley assembly connector.
- CHECK HARNESS AND CONNECTOR (COMPRESSOR WITH PULLEY ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Pre-procedure1
- Disconnect the C59 compressor with pulley assembly connector.
- Disconnect the H62 air conditioning amplifier assembly connector.
Procedure1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition C59-2 (SOL+) - H62-18 (SOL+) Always Below 1 Ω C59-1 (SOL-) - Body ground Always Below 1 Ω C59-2 (SOL+) or H62-18 (SOL+) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG Post-procedure1
- None
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [11/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR