Front Window Fogging [11/2023 - ]: Procedure
- CHECK REFRIGERANT SHORTAGE
- Prepare the vehicle according to the table below.MEASUREMENT CONDITION:
Item Condition A/C Switch On Ambient Temperature*1 0 to 49°C (32 to 120°F) Air Conditioning Air Inlet Temperature*2 25 to 35°C (77 to 95°F) Set Temperature MAX COLD Recirculation/fresh Control Switch Recirculation Air Vent Damper Position FACE Blower Speed HI HINT:
*1: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.
*2: This inspection can be judged correctly only if the air inlet temperature is within a range of 25 to 35°C (77 to 95°F). Therefore, postpone the test if the temperature is out of range.
- Using the GTS, check the amount of refrigerant.
Body Electrical > Air Conditioner > Utility
Tester Display Refrigerant Gas Volume Check NOTE:If the conditions for the inspection are not met, "Refrigerant incorrect" will be displayed on the GTS. Confirm the conditions of the inspection and perform the check again.
HINT:
- If the amount of refrigerant is insufficient, "Refrigerant shortage" is displayed on the GTS and the indicator light on the A/C switch turns off.
- When performing this inspection, a DTC will not be output even if "Refrigerant shortage" is displayed on the GTS.
Result
Result Amount of Refrigerant Refrigerant shortage Insufficient or leakage Refrigerant correct Correct Refrigerant incorrect Incorrect OK
"Refrigerant correct" is displayed on the GTS.
Result
Proceed to OK NG
Result:
NG
CHARGE SYSTEM WITH REFRIGERANT. Refer to REPLACEMENT [12/2019 - ]
Result:
OK
See step 2
- Prepare the vehicle according to the table below.
- CHECK OPERATION
- Check that the air conditioning system changes to DEF mode according to the switch operation, when the MODE switch on the air conditioning control assembly is pushed.
OK
Air conditioning system changes to DEF mode.
Result
Proceed to OK NG
Result:
OK
INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET. Refer to PROCEDURE - Step 1
Result:
NG
GO TO DTC B1403-7F. Refer to DTC B1403-7F: Front Air Outlet Damper Control Servo Motor Actuator Stuck Off [11/2023 - ]
- Check that the air conditioning system changes to DEF mode according to the switch operation, when the MODE switch on the air conditioning control assembly is pushed.