Air Vent Temperature does not Change and Right Vent is Different from Left and Vice Versa (Same Left/Right Temperature Setting) [11/2023 - ]: Procedure
- CHECK MALFUNCTION STATUS
Result
Result Proceed to Malfunction occurs during cooling A Malfunction occurs during heating B Result:
B
See step 6
Result:
A
See step 2
- CHECK REFRIGERANT SHORTAGE
- Prepare the vehicle according to the table below.MEASUREMENT CONDITION:
Item Condition A/C Switch On Ambient Temperature*1 0 to 49°C (32 to 120°F) Air Conditioning Air Inlet Temperature*2 25 to 35°C (77 to 95°F) Set Temperature MAX COLD Recirculation/fresh Control Switch Recirculation Air Vent Damper Position FACE Blower Speed HI HINT:
*1: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.
*2: This inspection can be judged correctly only if the air inlet temperature is within a range of 25 to 35°C (77 to 95°F). Therefore, postpone the test if the temperature is out of range.
- Using the GTS, check the amount of refrigerant.
Body Electrical > Air Conditioner > Utility
Tester Display Refrigerant Gas Volume Check NOTE:If the conditions for the inspection are not met, "Refrigerant incorrect" will be displayed on the GTS. Confirm the conditions of the inspection and perform the check again.
HINT:
- If the amount of refrigerant is insufficient, "Refrigerant shortage" is displayed on the GTS and the indicator light on the A/C switch turns off.
- When performing this inspection, a DTC will not be output even if "Refrigerant shortage" is displayed on the GTS.
Result
Result Amount of Refrigerant Refrigerant shortage Insufficient or leakage Refrigerant correct Correct Refrigerant incorrect Incorrect OK
"Refrigerant correct" is displayed on the GTS.
Result
Proceed to OK NG
Result:
NG
CHARGE SYSTEM WITH REFRIGERANT. Refer to REPLACEMENT [12/2019 - ]
Result:
OK
See step 3
- Prepare the vehicle according to the table below.
- PERFORM ACTIVE TEST USING GTS
- Perform the Active Test according to the display on the GTS.
Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Front Left Air Mix Damper Control Servo Motor This test activates the Front Left Air Mix Damper Control Servo Motor.
(No. 1 air conditioning radiator damper servo sub-assembly (front left side air mix))128: Min
384: MaxOperate with ignition switch ON. Front Right Air Mix Damper Control Servo Motor This test activates the Front Right Air Mix Damper Control Servo Motor.
(No. 1 air conditioning radiator damper servo sub-assembly (front right side air mix))128: Min
384: MaxOperate with ignition switch ON. Body Electrical > Air Conditioner > Active Test
Active Test Display Front Left Air Mix Damper Control Servo Motor Data List Display Front Left Air Mix Damper Control Servo Motor Actual Pulse Body Electrical > Air Conditioner > Active Test
Active Test Display Front Right Air Mix Damper Control Servo Motor Data List Display Front Right Air Mix Damper Control Servo Motor Actual Pulse OK
Damper servo motor is operated.
Result
Proceed to OK NG
Result:
NG
GO TO DIAGNOSTIC TROUBLE CODE CHART (FOR SERVO MOTOR OF APPLICABLE ABNORMAL OPERATION). Refer to DIAGNOSTIC TROUBLE CODE CHART [11/2023 - ]
Result:
OK
See step 4
- Perform the Active Test according to the display on the GTS.
- CHECK HARNESS AND CONNECTOR (SOLAR SENSOR (AUTOMATIC LIGHT CONTROL SENSOR) - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))
- Disconnect the G5 solar sensor (automatic light control sensor) connector.
- Disconnect the H135 main body ECU (multiplex network body ECU) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G5-1 (CLTB) - H135-8 (CLTB) Always Below 1 Ω G5-2 (CLTE) - H135-21 (CLTE) Always Below 1 Ω G5-4 (CLTS) - H135-20 (CLTS) Always Below 1 Ω G5-1 (CLTB) or H135-8 (CLTB) - Other terminals and body ground Always 10 kΩ or higher G5-2 (CLTE) or H135-21 (CLTE) - Other terminals and body ground Always 10 kΩ or higher G5-4 (CLTS) or H135-20 (CLTS) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 5
- INSPECT SOLAR SENSOR (AUTOMATIC LIGHT CONTROL SENSOR)
Refer to ON-VEHICLE INSPECTION [12/2019 - ]
Result
Proceed to OK NG Result:
OK
INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET. Refer to ON-VEHICLE INSPECTION [12/2019 - ]
Result:
NG
REPLACE SOLAR SENSOR (AUTOMATIC LIGHT CONTROL SENSOR). Refer to REMOVAL [12/2019 - ]
- BLEED AIR FROM COOLANT (COOLING SYSTEM)
Refer to REPLACEMENT [10/2022 - ]
Result
Proceed to NEXT Result:
NEXT
See step 7
- CHECK OPERATION (AIR CONDITIONING SYSTEM)
- Set the same temperature for the left and right sides and check that the air that blows from the left and right front registers is the same temperature.
OK
The air from the left and right front registers is the same temperature.
Result
Proceed to OK NG
Result:
OK
END (FAILURE DUE TO AIR ENTERING COOLANT)
Result:
NG
See step 8
- Set the same temperature for the left and right sides and check that the air that blows from the left and right front registers is the same temperature.
- PERFORM ACTIVE TEST USING GTS
- Perform the Active Test according to the display on the GTS.
Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Front Left Air Mix Damper Control Servo Motor This test activates the Front Left Air Mix Damper Control Servo Motor.
(No. 1 air conditioning radiator damper servo sub-assembly (front left side air mix))128: Min
384: MaxOperate with ignition switch ON. Front Right Air Mix Damper Control Servo Motor This test activates the Front Right Air Mix Damper Control Servo Motor.
(No. 1 air conditioning radiator damper servo sub-assembly (front right side air mix))128: Min
384: MaxOperate with ignition switch ON. Body Electrical > Air Conditioner > Active Test
Active Test Display Front Left Air Mix Damper Control Servo Motor Data List Display Front Left Air Mix Damper Control Servo Motor Actual Pulse Body Electrical > Air Conditioner > Active Test
Active Test Display Front Right Air Mix Damper Control Servo Motor Data List Display Front Right Air Mix Damper Control Servo Motor Actual Pulse OK
Damper servo motor is operated.
Result
Proceed to OK NG
Result:
OK
REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY. Refer to DISASSEMBLY [11/2023 - ]
Result:
NG
GO TO DIAGNOSTIC TROUBLE CODE CHART (FOR SERVO MOTOR OF APPLICABLE ABNORMAL OPERATION). Refer to DIAGNOSTIC TROUBLE CODE CHART [11/2023 - ]
- Perform the Active Test according to the display on the GTS.