DTC C13E9-1C: 4WD/AWD Left Range Actuator Control Circuit Performance Circuit Voltage Out of Range [12/2019 - ]: Procedure
- CHECK HARNESS AND CONNECTOR (4WD ECU ASSEMBLY - REAR 4WD LINEAR SOLENOID LH (ELECTRO MAGNETIC CONTROL COUPLING SUB-ASSEMBLY LH))
- Disconnect the M42 4WD ECU assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition M42-4 (WJSL) - M42-3 (WJRL) 20°C (68°F) 2.2 to 2.6 Ω M42-4 (WJSL) - Body ground Always 10 kΩ or higher - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition M42-3 (WJRL) - Body ground Always Below 1 V Result
Proceed to OK NG
Result:
OK
REPLACE 4WD ECU ASSEMBLY. Refer to REMOVAL [12/2019 - ]
Result:
NG
See step 2
- CHECK HARNESS AND CONNECTOR (4WD ECU ASSEMBLY - REAR 4WD LINEAR SOLENOID LH (ELECTRO MAGNETIC CONTROL COUPLING SUB-ASSEMBLY LH))
- Disconnect the M42 4WD ECU assembly connector.
- Disconnect the s3 rear 4WD linear solenoid LH (electro magnetic control coupling sub-assembly LH) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition M42-4 (WJSL) - s3-1 (WJSL) Always Below 1 Ω M42-3 (WJRL) - s3-2 (WJRL) Always Below 1 Ω M42-4 (WJSL) or s3-1 (WJSL) - Body ground Always 10 kΩ or higher M42-3 (WJRL) or s3-2 (WJRL) - Body ground Always 10 kΩ or higher M42-4 (WJSL) or s3-1 (WJSL) - M42-3 (WJRL) or s3-2 (WJRL) Always 10 kΩ or higher - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition M42-3 (WJRL) or s3-2 (WJRL) - Body ground Always Below 1 V Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 3
- INSPECT REAR 4WD LINEAR SOLENOID LH (ELECTRO MAGNETIC CONTROL COUPLING SUB-ASSEMBLY LH)
- Disconnect the s3 rear 4WD linear solenoid LH (electro magnetic control coupling sub-assembly LH) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition s3-1 (WJSL) - s3-2 (WJRL) 20°C (68°F) 2.2 to 2.6 Ω Result
Proceed to OK NG
Result:
OK
CHECK INTERMITTENT PROBLEMS. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [12/2019 - ]
Result:
NG
REPLACE ELECTRO MAGNETIC CONTROL COUPLING SUB-ASSEMBLY LH. Refer to DISASSEMBLY [12/2019 - ]