Typical Malfunction Thresholds
OFF malfunction
- Any of the following conditions are met: OFF malfunction (A), (B) or (C)OFF MALFUNCTION (A) AND (B)
Neutral state flag ON OFF MALFUNCTION (C)Solenoid (SLT) valve ON malfunction
ON malfunction
- Any of the following conditions are met: ON malfunction (A), (B), (C), (D), (E) or (F)ON MALFUNCTION (A), (B) AND (C)
Any of the following conditions are met (a) or (b) (a) Turbine speed/Output speed (NT/NO) 1.910 or more and 2.189 or less
(When output speed less than 350 rpm)(b) Turbine speed - Output speed x 3rd gear ratio -50 rpm or more and 50 rpm or less
(When output speed 350 rpm or more)ON MALFUNCTION (D) AND (E)Any of the following conditions are met (a) or (b) (a) Turbine speed/Output speed (NT/NO) 0.737 or more and 0.867 or less
(When output speed less than 750 rpm)(b) Turbine speed - Output speed x 7th gear ratio -50 rpm or more and 50 rpm or less
(When output speed 750 rpm or more)ON MALFUNCTION (F)Solenoid (SLT) valve ON malfunction - Any of the following conditions are met: Condition (a), (b) or (c)CONDITION (A)
ECM selected gear 4th 4th gear pass detection Not fixed after transition to latest gear CONDITION (B)ECM selected gear 5th 5th gear pass detection Not fixed after transition to latest gear CONDITION (C)ECM selected gear 8th 8th gear pass detection Not fixed after transition to latest gear
- Any of the following conditions are met: Condition (a), (b) or (c)
HINT:
NEUTRAL STATE FLAG:
| Turbine speed - Output speed x (ECM selected gear ratio) | 1000 rpm or more |