DTC P08BA-7F: Pressure Control Solenoid "L" Actuator Stuck Off [12/2019 - 10/2022]: Procedure
- CHECK DTC OUTPUT (IN ADDITION TO DTC P08BA-7F)
- Read the DTCs using the GTS.
Powertrain > Transmission > Trouble Codes
Result
Result Proceed to DTC P08BA-7F and DTC P0740-7E, P0745-7F, P0775-7F, P0795-7F, P2713-7F, P2816-7F and/or P2807-7F are output A Only DTC P08BA-7F is output B DTCs other than P0740-7E, P0745-7F, P0775-7F, P0795-7F, P08BA-7F, P2713-7F, P2807-7F and P2816-7F are also output C HINT:
- If any DTCs other than P0740-7E, P0745-7F, P0775-7F, P0795-7F, P08BA-7F, P2713-7F, P2807-7F and P2816-7F are output, perform troubleshooting for those DTCs first.
- If a solenoid valve is stuck ON or OFF, DTCs for several solenoid valves including the malfunctioning solenoid valve will be stored.
Result:
B
See step 3
Result:
C
GO TO DTC CHART. Refer to DIAGNOSTIC TROUBLE CODE CHART [12/2019 - 10/2021] , or refer to DIAGNOSTIC TROUBLE CODE CHART [10/2021 - 10/2022]
Result:
A
See step 2
- Read the DTCs using the GTS.
- CLEAR DTC AND PERFORM STALL SPEED TEST
- Clear the DTCs.
Powertrain > Transmission > Clear DTCs
HINT:
Write down the currently output DTCs before clearing them.
- Perform the stall speed test.
Refer to MECHANICAL SYSTEM TESTS [12/2019 - 10/2022]
Result
Test Condition Proceed to Stall speed test can be performed A Stall speed test cannot be performed B
Result:
B
See step 5
Result:
A
See step 3
- Clear the DTCs.
- INSPECT SOLENOID (SL1), (SL2), (SL3), (SL4), (SL5) AND (SL6) VALVE
- Remove the solenoid (SL1), (SL2), (SL3), (SL4), (SL5) and (SL6) valves.
*a Component without harness connected
(Solenoid (SL1), (SL2), (SL3), (SL4), (SL5) and (SL6) Valves)Refer to DISASSEMBLY [12/2019 - 10/2022]
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Solenoid (SL1) valve connector terminal 1 - terminal 2 20°C (68°F) 5.0 to 5.6 Ω Solenoid (SL2) valve connector terminal 1 - terminal 2 20°C (68°F) 5.0 to 5.6 Ω Solenoid (SL3) valve connector terminal 1 - terminal 2 20°C (68°F) 5.0 to 5.6 Ω Solenoid (SL4) valve connector terminal 1 - terminal 2 20°C (68°F) 5.0 to 5.6 Ω Solenoid (SL5) valve connector terminal 1 - terminal 2 20°C (68°F) 5.0 to 5.6 Ω Solenoid (SL6) valve connector terminal 1 - terminal 2 20°C (68°F) 5.0 to 5.6 Ω - Connect a positive (+) lead from the battery with a 21 W bulb to terminal 1 and a negative (-) lead to terminal 2 of the solenoid valve connector. Check that the valve moves and makes an operating sound.
OK
Valve moves and makes an operating sound.
Result
Proceed to OK NG
Result:
NG
REPLACE SOLENOID (SL1), (SL2), (SL3), (SL4), (SL5) OR (SL6) VALVE. Refer to COMPONENTS [12/2019 - 10/2022]
Result:
OK
See step 4
- Remove the solenoid (SL1), (SL2), (SL3), (SL4), (SL5) and (SL6) valves.
- INSPECT SOLENOID (SL) VALVE
- Remove the solenoid (SL) valve.
*1 Solenoid (SL) Valve Refer to DISASSEMBLY [12/2019 - 10/2022]
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Solenoid (SL) valve connector terminal - Solenoid (SL) valve body 20°C (68°F) 11 to 15 Ω - Connect a positive (+) lead from the battery to the terminal of the solenoid valve connector, and a negative (-) lead to the solenoid body. Check that the valve moves and makes an operating sound.
OK
Valve moves and makes an operating sound.
Result
Proceed to OK NG
Result:
NG
REPLACE SOLENOID (SL) VALVE. Refer to COMPONENTS [12/2019 - 10/2022]
Result:
OK
See step 5
- Remove the solenoid (SL) valve.
- INSPECT SOLENOID (SLT) VALVE
- Remove the solenoid (SLT) valve.
*a Component without harness connected
(Solenoid (SLT) Valve)Refer to DISASSEMBLY [12/2019 - 10/2022]
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Solenoid (SLT) valve connector terminal 1 - terminal 2 20°C (68°F) 5.0 to 5.6 Ω - Connect a positive (+) lead from the battery with a 21 W bulb to terminal 1 and a negative (-) lead to terminal 2 of the solenoid valve connector. Check that the valve moves and makes an operating sound.
OK
Valve moves and makes an operating sound.
Result
Proceed to OK NG
Result:
NG
REPLACE SOLENOID (SLT) VALVE. Refer to COMPONENTS [12/2019 - 10/2022]
Result:
OK
See step 6
- Remove the solenoid (SLT) valve.
- INSPECT TRANSMISSION VALVE BODY ASSEMBLY
- Inspect the transmission valve body assembly.
Refer to REMOVAL [12/2019 - 10/2022]
OK
There is no foreign matter on each valve and they operate smoothly.
Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE TRANSMISSION VALVE BODY ASSEMBLY. Refer to COMPONENTS [12/2019 - 10/2022]
Result:
OK
See step 7
- Inspect the transmission valve body assembly.
- INSPECT TORQUE CONVERTER ASSEMBLY
- Inspect the torque converter assembly.
Refer to INSPECTION [12/2019 - 10/2022]
OK
The torque converter assembly is normal.
Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE TORQUE CONVERTER ASSEMBLY. Refer to COMPONENTS [12/2019 - 10/2022]
Result:
OK
See step 8
- Inspect the torque converter assembly.
- REPAIR OR REPLACE AUTOMATIC TRANSAXLE ASSEMBLY
- Repair or replace the automatic transaxle assembly.
Refer to COMPONENTS [12/2019 - 10/2022]
Result
Proceed to NEXT
Result:
NEXT
PERFORM REGISTRATION. Refer to REGISTRATION [12/2019 - 10/2022]
- Repair or replace the automatic transaxle assembly.