DSD Information System
Home >> Toyota >> 2021 >> Highlander LE, 4WD >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Automatic Transmission System (UA80F) - Diagnostic Codes (2 Of 2) & Symptom Tests >> Automatic Transaxle System >> DTC P2713-7F: Pressure Control Solenoid "D" Actuator Stuck Off [12/2019 - 10/2022] >> Typical Enabling Conditions

Typical Enabling Conditions

ALL

The monitor will run whenever the following DTCs are not stored P0717, P07BF, P07C0 (Turbine speed sensor circuit)
P0793, P07C5, P07C6 (Intermediate shaft speed sensor circuit)
P0712, P0713 (ATF temperature sensor circuit (TFT sensor))
P0962, P0963 (Solenoid (SL1) valve circuit)
P0966, P0967 (Solenoid (SL2) valve circuit)
P0970, P0971 (Solenoid (SL3) valve circuit)
P2814, P2815 (Solenoid (SL4) valve circuit)
P281D, P281E (Solenoid (SL5) valve circuit)
P08C1, P08C2 (Solenoid (SL6) valve circuit)
P2769, P2770 (Solenoid (SL) valve circuit)
P2763, P2764 (Solenoid (SLU) valve circuit)
P2720, P2721 (Solenoid (SLT) valve circuit)
P0117, P0118 (ECT sensor circuit)
P0335, P0337, P0338 (Crankshaft position sensor circuit)
P0327, P0328, P0332, P0333 (KCS sensor circuit)
P0121, P0122, P0123, P0222, P0223, P0604, P0606, P060A, P060B, P060D, P060E, P061E, P0657, P0658, P2102, P2103, P2111, P2112, P2119, P2135 ((ETCS) Electronic throttle control system)
U0100 (CAN communication system)
Shift position "D", "not R" and "not N"
Elapsed time since shift lever moved from "N" to "D" 4 sec. or more
ATF temperature -10°C (14°F) or more
Engine Starting

ON malfunction (A) 

  1. START CONDITIONS OF J1SUMMAX CALCULATION

    Turbine speed 270 rpm or more
    Neutral state under low torque flag OFF
    ECM selected gear 1st
    Time after transition to 1st gear -
    - when detected abnormal shift 1.5 sec. or more
    - when not detected abnormal shift Immediately after approval
    Turbine speed - Output speed x 1st gear ratio 150 rpm or more
    Output speed More than 0 rpm
    Calculated input torque when the following conditions are met: (a), (b) and (c) Specified value
    (a) ECM selected gear 1st
    (b) Time after transition to 1st gear -
    - when detected abnormal shift 1.5 sec. or more
    - when not detected abnormal shift Immediately after approval
    (c) Turbine speed - Output speed x 1st gear ratio 150 rpm or more
    FINISH CONDITIONS OF J1SUMMAX CALCULATION

    Any of the following conditions are met: (a), (b), (c), (d), (e) or (f) -
    (a) Turbine speed Less than 270 rpm
    (b) Neutral state under low torque flag ON
    (c) ECM selected gear Not 1st
    (d) Duration time while following condition met 0 sec. or more
    Turbine speed - Output speed x 1st gear ratio Less than 50 rpm
    (e) Pass condition met -
    (f) ECM selected gear Neutral

ON malfunction (B) 

  1. START CONDITIONS OF J2SUMMAX CALCULATION

    Turbine speed 270 rpm or more
    Neutral state under low torque flag OFF
    ECM selected gear 2nd
    Time after transition to 2nd gear -
    - when detected abnormal shift 1.5 sec. or more
    - when not detected abnormal shift Immediately after approval
    Turbine speed - Output speed x 2nd gear ratio 150 rpm or more
    Output speed More than 0 rpm
    Calculated input torque when the following conditions are met: (a), (b) and (c) Specified value
    (a) ECM selected gear 2nd
    (b) Time after transition to 2nd gear -
    - when detected abnormal shift 1.5 sec. or more
    - when not detected abnormal shift Immediately after approval
    (c) Turbine speed - Output speed x 2nd gear ratio 150 rpm or more
    FINISH CONDITIONS OF J2SUMMAX CALCULATION

    Any of the following conditions are met: (a), (b), (c), (d), (e) or (f) -
    (a) Turbine speed Less than 270 rpm
    (b) Neutral state under low torque flag ON
    (c) ECM selected gear Not 2nd
    (d) Duration time while following condition met 0 sec. or more
    Turbine speed - Output speed x 2nd gear ratio Less than 50 rpm
    (e) Pass condition met -
    (f) ECM selected gear Neutral

ON malfunction (C) 

  1. START CONDITIONS OF J3SUMMAX CALCULATION

    Turbine speed 270 rpm or more
    Neutral state under low torque flag OFF
    ECM selected gear 3rd
    Time after transition to 3rd gear -
    - when detected abnormal shift 1.5 sec. or more
    - when not detected abnormal shift Immediately after approval
    Turbine speed - Output speed x 3rd gear ratio 150 rpm or more
    Output speed More than 0 rpm
    Calculated input torque when the following conditions are met: (a), (b) and (c) Specified value
    (a) ECM selected gear 3rd
    (b) Time after transition to 3rd gear -
    - when detected abnormal shift 1.5 sec. or more
    - when not detected abnormal shift Immediately after approval
    (c) Turbine speed - Output speed x 3rd gear ratio 150 rpm or more
    FINISH CONDITIONS OF J3SUMMAX CALCULATION

    Any of the following conditions are met: (a), (b), (c), (d), (e) or (f) -
    (a) Turbine speed Less than 270 rpm
    (b) Neutral state under low torque flag ON
    (c) ECM selected gear Not 3rd
    (d) Duration time while following condition met 0 sec. or more
    Turbine speed - Output speed x 3rd gear ratio Less than 50 rpm
    (e) Pass condition met -
    (f) ECM selected gear Neutral

ON malfunction (D) 

  1. START CONDITIONS OF J4SUMMAX CALCULATION

    Turbine speed 270 rpm or more
    Neutral state under low torque flag OFF
    ECM selected gear 4th
    Time after transition to 4th gear -
    - when detected abnormal shift 1.5 sec. or more
    - when not detected abnormal shift Immediately after approval
    Turbine speed - Output speed x 4th gear ratio 150 rpm or more
    Output speed More than 0 rpm
    Calculated input torque when the following conditions are met: (a), (b) and (c) Specified value
    (a) ECM selected gear 4th
    (b) Time after transition to 4th gear -
    - when detected abnormal shift 1.5 sec. or more
    - when not detected abnormal shift Immediately after approval
    (c) Turbine speed - Output speed x 4th gear ratio 150 rpm or more
    FINISH CONDITIONS OF J4SUMMAX CALCULATION

    Any of the following conditions are met: (a), (b), (c), (d), (e) or (f) -
    (a) Turbine speed Less than 270 rpm
    (b) Neutral state under low torque flag ON
    (c) ECM selected gear Not 4th
    (d) Duration time while following condition met 0 sec. or more
    Turbine speed - Output speed x 4th gear ratio Less than 50 rpm
    (e) Pass condition met -
    (f) ECM selected gear Neutral

ON malfunction (E) 

  1. START CONDITIONS OF J5SUMMAX CALCULATION

    Turbine speed 270 rpm or more
    Neutral state under low torque flag OFF
    ECM selected gear 5th
    Time after transition to 5th gear -
    - when detected abnormal shift 1.5 sec. or more
    - when not detected abnormal shift Immediately after approval
    Turbine speed - Output speed x 5th gear ratio 150 rpm or more
    Output speed More than 0 rpm
    Calculated input torque when the following conditions are met: (a), (b) and (c) Specified value
    (a) ECM selected gear 5th
    (b) Time after transition to 5th gear -
    - when detected abnormal shift 1.5 sec. or more
    - when not detected abnormal shift Immediately after approval
    (c) Turbine speed - Output speed x 5th gear ratio 150 rpm or more
    FINISH CONDITIONS OF J5SUMMAX CALCULATION

    Any of the following conditions are met: (a), (b), (c), (d), (e) or (f) -
    (a) Turbine speed Less than 270 rpm
    (b) Neutral state under low torque flag ON
    (c) ECM selected gear Not 5th
    (d) Duration time while following condition met 0 sec. or more
    Turbine speed - Output speed x 5th gear ratio Less than 50 rpm
    (e) Pass condition met -
    (f) ECM selected gear Neutral

ON malfunction (F) 

  1. START CONDITIONS OF J6SUMMAX CALCULATION

    Turbine speed 270 rpm or more
    Neutral state under low torque flag OFF
    ECM selected gear 6th
    Time after transition to 6th gear -
    - when detected abnormal shift 1.5 sec. or more
    - when not detected abnormal shift Immediately after approval
    Turbine speed - Output speed x 6th gear ratio 150 rpm or more
    Output speed More than 0 rpm
    Calculated input torque when the following conditions are met: (a), (b) and (c) Specified value
    (a) ECM selected gear 6th
    (b) Time after transition to 6th gear -
    - when detected abnormal shift 1.5 sec. or more
    - when not detected abnormal shift Immediately after approval
    (c) Turbine speed - Output speed x 6th gear ratio 150 rpm or more
    FINISH CONDITIONS OF J6SUMMAX CALCULATION

    Any of the following conditions are met: (a), (b), (c), (d), (e) or (f) -
    (a) Turbine speed Less than 270 rpm
    (b) Neutral state under low torque flag ON
    (c) ECM selected gear Not 6th
    (d) Duration time while following condition met 0 sec. or more
    Turbine speed - Output speed x 6th gear ratio Less than 50 rpm
    (e) Pass condition met -
    (f) ECM selected gear Neutral

ON malfunction (G) 

  1. START CONDITIONS OF J7SUMMAX CALCULATION

    Turbine speed 270 rpm or more
    Neutral state under low torque flag OFF
    ECM selected gear 7th
    Time after transition to 7th gear -
    - when detected abnormal shift 1.5 sec. or more
    - when not detected abnormal shift Immediately after approval
    Turbine speed - Output speed x 7th gear ratio 150 rpm or more
    Output speed More than 0 rpm
    Calculated input torque when the following conditions are met: (a), (b) and (c) Specified value
    (a) ECM selected gear 7th
    (b) Time after transition to 7th gear -
    - when detected abnormal shift 1.5 sec. or more
    - when not detected abnormal shift Immediately after approval
    (c) Turbine speed - Output speed x 7th gear ratio 150 rpm or more
    FINISH CONDITIONS OF J7SUMMAX CALCULATION

    Any of the following conditions are met: (a), (b), (c), (d), (e) or (f) -
    (a) Turbine speed Less than 270 rpm
    (b) Neutral state under low torque flag ON
    (c) ECM selected gear Not 7th
    (d) Duration time while following condition met 0 sec. or more
    Turbine speed - Output speed x 7th gear ratio Less than 50 rpm
    (e) Pass condition met -
    (f) ECM selected gear Neutral

ON malfunction (H) 

  1. START CONDITIONS OF J8SUMMAX CALCULATION

    Turbine speed 270 rpm or more
    Neutral state under low torque flag OFF
    ECM selected gear 8th
    Time after transition to 8th gear -
    - when detected abnormal shift 1.5 sec. or more
    - when not detected abnormal shift Immediately after approval
    Turbine speed - Output speed x 8th gear ratio 150 rpm or more
    Output speed More than 0 rpm
    Calculated input torque when the following conditions are met: (a), (b) and (c) Specified value
    (a) ECM selected gear 8th
    (b) Time after transition to 8th gear -
    - when detected abnormal shift 1.5 sec. or more
    - when not detected abnormal shift Immediately after approval
    (c) Turbine speed - Output speed x 8th gear ratio 150 rpm or more
    FINISH CONDITIONS OF J8SUMMAX CALCULATION

    Any of the following conditions are met: (a), (b), (c), (d), (e) or (f) -
    (a) Turbine speed Less than 270 rpm
    (b) Neutral state under low torque flag ON
    (c) ECM selected gear Not 8th
    (d) Duration time while following condition met 0 sec. or more
    Turbine speed - Output speed x 8th gear ratio Less than 50 rpm
    (e) Pass condition met -
    (f) ECM selected gear Neutral

ON malfunction (J) 

  1. ECM selected gear 4th

ON malfunction (K) and (L) 

  1. ECM selected gear 8th

ON malfunction (N) 

  1. Fail-safe mode flag OFF
    ECM selected gear 3rd
    ON malfunction condition (Q) Fixed

ON malfunction (O) 

  1. Fail-safe mode flag OFF
    ECM selected gear 5th
    ON malfunction condition (R) Fixed

ON malfunction (P) 

  1. Fail-safe mode flag OFF
    ECM selected gear 4th
    ON malfunction condition (S) Fixed

ON malfunction (Q) 

  1. ECM selected gear 1st or 2nd
    Neutral state flag ON
    Calculated input torque when Neutral state flag ON Specified value
    1st gear pass detection Not fixed (after transition to latest gear)
    2nd gear pass detection Not fixed (after transition to latest gear)
    Output speed x 3rd gear ratio Less than 6500 rpm

ON malfunction (R) 

  1. ECM selected gear 3rd, 4th, 6th, 7th or 8th
    Neutral state flag ON
    Calculated input torque when Neutral state flag ON Specified value
    Output speed x 5th gear ratio Less than 6500 rpm
    1. Any of the following conditions are met: condition (a) or (b)
      CONDITION (A)

      ECM selected gear 8th
      8th gear pass detection Not fixed (after transition to latest gear)
      CONDITION (B)

      Following conditions are met (1) and (((2), (3), (4) and (5)) or (6))
      (1) ECM selected gear 3rd, 4th, 6th or 7th
      (2) 3rd gear pass detection Not fixed (after transition to latest gear)
      (3) 4th gear pass detection Not fixed (after transition to latest gear)
      (4) 6th gear pass detection Not fixed (after transition to latest gear)
      (5) 7th gear pass detection Not fixed (after transition to latest gear)
      (6) ECM commanded solenoid (SL) valve state OFF (after transition to latest gear)
    2. Any of the following conditions are met: condition (a), (b), (c) or (d)
      CONDITION (A)

      ECM selected gear 4th or 7th
      Turbine speed - Output speed x 3rd gear ratio More than 50 rpm
      CONDITION (B)

      ECM selected gear 6th
      Turbine speed - Output speed x 4th gear ratio More than 50 rpm
      CONDITION (C)

      ECM selected gear 8th
      Turbine speed - Output speed x 5th gear ratio More than 50 rpm
      CONDITION (D)

      ECM selected gear 3rd

ON malfunction (S) 

  1. ECM selected gear 5th
    Neutral state flag ON
    Calculated input torque when Neutral state flag ON Specified value
    5th gear pass detection Not fixed (after transition to latest gear)
    Turbine speed - Output speed x 3rd gear ratio More than 50 rpm
    Output speed x 4th gear ratio Less than 6500 rpm

OFF malfunction 

  1. Fail-safe function does not operate due to the following malfunctions: -
    Solenoid (SL1) valve Not OFF or ON malfunction (P0746)
    Solenoid (SL2) valve Not OFF or ON malfunction (P0776)
    Solenoid (SL3) valve Not OFF or ON malfunction (P0796)
    Solenoid (SL4) valve Not OFF or ON malfunction (P2808)
    Solenoid (SL5) valve Not OFF or ON malfunction (P2817)
    Solenoid (SL6) valve Not OFF or ON malfunction (P08BB)
    Solenoid (SLT) valve Not OFF malfunction (P2714)
    Solenoid (SLU) valve Not ON malfunction (P2757)
    Solenoid (SL) valve Not ON malfunction (P0741)
    All shift solenoids Not being stopped
    Neutral command flag Not met
    ECM selected gear 2nd, 3rd, 4th, 6th, 7th or 8th
    Vehicle speed 2 km/h (1.2 mph) or more
    Throttle valve opening angle 5% or more at engine speed 2000 rpm
    (conditions vary with engine speed)
    Calculated load value -
    - When A/C off 16.0% or more
    - When A/C on 19.0% or more
    ECT 40°C (104°F) or more
    Spark advance from MAX. retard timing by KCS control 0 °CA or more

HINT: 

NEUTRAL STATE UNDER LOW TORQUE FLAG

Neutral state flag ON
ECM selected gear 1st, 2nd, 3rd, 4th, 5th, 6th, 7th or 8th
Fail-safe mode flag OFF
  1. Any of the following conditions are met: Condition (a) or (b)
    1. CONDITION (A)

      ECM selected gear 1st, 2nd, 5th or 8th
      1st gear pass detection Not fixed (after transition to latest gear)
      2nd gear pass detection Not fixed (after transition to latest gear)
      5th gear pass detection Not fixed (after transition to latest gear)
      8th gear pass detection Not fixed (after transition to latest gear)
      CONDITION (B)

      Following conditions are met (1) and (((2), (3), (4) and (5)) or (6))
      (1) ECM selected gear 3rd, 4th, 6th or 7th
      (2) 3rd gear pass detection Not fixed (after transition to latest gear)
      (3) 4th gear pass detection Not fixed (after transition to latest gear)
      (4) 6th gear pass detection Not fixed (after transition to latest gear)
      (5) 7th gear pass detection Not fixed (after transition to latest gear)
      (6) ECM commanded solenoid (SL) valve state OFF (after transition to latest gear)
  1. Any of the following conditions are met: Condition (a), (b), (c) or (d)
    CONDITION (A)

    ECM selected gear 4th, 5th or 7th
    Turbine speed - Output speed x 3rd gear ratio More than 50 rpm
    CONDITION (B)

    ECM selected gear 6th
    Turbine speed - Output speed x 4th gear ratio More than 50 rpm
    CONDITION (C)

    ECM selected gear 8th
    Turbine speed - Output speed x 5th gear ratio More than 50 rpm
    CONDITION (D)

    ECM selected gear 1st, 2nd or 3rd
NEUTRAL STATE FLAG:

Turbine speed - output speed x (ECM selected gear ratio) 1000 rpm or more
NEUTRAL COMMAND FLAG:

Engine speed 7200 rpm or more
Turbine speed 7200 rpm or more
  1. Any of the following conditions are met: Condition (a) or (b)
    1. Condition (a)
      ECM selected gear 6th or 7th or 8th
      Output speed x 5th gear ratio 7200 rpm or more

      Condition (b)

      ECM selected gear 4th or 5th
      Output speed x 3rd gear ratio 7200 rpm or more