Typical Enabling Conditions
ALL
| The monitor will run whenever the following DTCs are not stored | P0717, P07BF, P07C0 (Turbine speed sensor circuit) P0793, P07C5, P07C6 (Intermediate shaft speed sensor circuit) P0712, P0713 (ATF temperature sensor circuit (TFT sensor)) P0962, P0963 (Solenoid (SL1) valve circuit) P0966, P0967 (Solenoid (SL2) valve circuit) P0970, P0971 (Solenoid (SL3) valve circuit) P2814, P2815 (Solenoid (SL4) valve circuit) P281D, P281E (Solenoid (SL5) valve circuit) P08C1, P08C2 (Solenoid (SL6) valve circuit) P2769, P2770 (Solenoid (SL) valve circuit) P2763, P2764 (Solenoid (SLU) valve circuit) P2720, P2721 (Solenoid (SLT) valve circuit) P0117, P0118 (ECT sensor circuit) P0335, P0337, P0338 (Crankshaft position sensor circuit) P0327, P0328, P0332, P0333 (KCS sensor circuit) P0121, P0122, P0123, P0222, P0223, P0604, P0606, P060A, P060B, P060D, P060E, P061E, P0657, P0658, P2102, P2103, P2111, P2112, P2119, P2135 ((ETCS) Electronic throttle control system) U0100 (CAN communication system) |
| Shift position | "D", "not R" and "not N" |
| Elapsed time since shift lever moved from "N" to "D" | 4 sec. or more |
| ATF temperature | -10°C (14°F) or more |
| Engine | Starting |
ON malfunction (A)
- START CONDITIONS OF J1SUMMAX CALCULATION
Turbine speed 270 rpm or more Neutral state under low torque flag OFF ECM selected gear 1st Time after transition to 1st gear - - when detected abnormal shift 1.5 sec. or more - when not detected abnormal shift Immediately after approval Turbine speed - Output speed x 1st gear ratio 150 rpm or more Output speed More than 0 rpm Calculated input torque when the following conditions are met: (a), (b) and (c) Specified value (a) ECM selected gear 1st (b) Time after transition to 1st gear - - when detected abnormal shift 1.5 sec. or more - when not detected abnormal shift Immediately after approval (c) Turbine speed - Output speed x 1st gear ratio 150 rpm or more FINISH CONDITIONS OF J1SUMMAX CALCULATIONAny of the following conditions are met: (a), (b), (c), (d), (e) or (f) - (a) Turbine speed Less than 270 rpm (b) Neutral state under low torque flag ON (c) ECM selected gear Not 1st (d) Duration time while following condition met 0 sec. or more Turbine speed - Output speed x 1st gear ratio Less than 50 rpm (e) Pass condition met - (f) ECM selected gear Neutral
ON malfunction (B)
- START CONDITIONS OF J2SUMMAX CALCULATION
Turbine speed 270 rpm or more Neutral state under low torque flag OFF ECM selected gear 2nd Time after transition to 2nd gear - - when detected abnormal shift 1.5 sec. or more - when not detected abnormal shift Immediately after approval Turbine speed - Output speed x 2nd gear ratio 150 rpm or more Output speed More than 0 rpm Calculated input torque when the following conditions are met: (a), (b) and (c) Specified value (a) ECM selected gear 2nd (b) Time after transition to 2nd gear - - when detected abnormal shift 1.5 sec. or more - when not detected abnormal shift Immediately after approval (c) Turbine speed - Output speed x 2nd gear ratio 150 rpm or more FINISH CONDITIONS OF J2SUMMAX CALCULATIONAny of the following conditions are met: (a), (b), (c), (d), (e) or (f) - (a) Turbine speed Less than 270 rpm (b) Neutral state under low torque flag ON (c) ECM selected gear Not 2nd (d) Duration time while following condition met 0 sec. or more Turbine speed - Output speed x 2nd gear ratio Less than 50 rpm (e) Pass condition met - (f) ECM selected gear Neutral
ON malfunction (C)
- START CONDITIONS OF J3SUMMAX CALCULATION
Turbine speed 270 rpm or more Neutral state under low torque flag OFF ECM selected gear 3rd Time after transition to 3rd gear - - when detected abnormal shift 1.5 sec. or more - when not detected abnormal shift Immediately after approval Turbine speed - Output speed x 3rd gear ratio 150 rpm or more Output speed More than 0 rpm Calculated input torque when the following conditions are met: (a), (b) and (c) Specified value (a) ECM selected gear 3rd (b) Time after transition to 3rd gear - - when detected abnormal shift 1.5 sec. or more - when not detected abnormal shift Immediately after approval (c) Turbine speed - Output speed x 3rd gear ratio 150 rpm or more FINISH CONDITIONS OF J3SUMMAX CALCULATIONAny of the following conditions are met: (a), (b), (c), (d), (e) or (f) - (a) Turbine speed Less than 270 rpm (b) Neutral state under low torque flag ON (c) ECM selected gear Not 3rd (d) Duration time while following condition met 0 sec. or more Turbine speed - Output speed x 3rd gear ratio Less than 50 rpm (e) Pass condition met - (f) ECM selected gear Neutral
ON malfunction (D)
- START CONDITIONS OF J4SUMMAX CALCULATION
Turbine speed 270 rpm or more Neutral state under low torque flag OFF ECM selected gear 4th Time after transition to 4th gear - - when detected abnormal shift 1.5 sec. or more - when not detected abnormal shift Immediately after approval Turbine speed - Output speed x 4th gear ratio 150 rpm or more Output speed More than 0 rpm Calculated input torque when the following conditions are met: (a), (b) and (c) Specified value (a) ECM selected gear 4th (b) Time after transition to 4th gear - - when detected abnormal shift 1.5 sec. or more - when not detected abnormal shift Immediately after approval (c) Turbine speed - Output speed x 4th gear ratio 150 rpm or more FINISH CONDITIONS OF J4SUMMAX CALCULATIONAny of the following conditions are met: (a), (b), (c), (d), (e) or (f) - (a) Turbine speed Less than 270 rpm (b) Neutral state under low torque flag ON (c) ECM selected gear Not 4th (d) Duration time while following condition met 0 sec. or more Turbine speed - Output speed x 4th gear ratio Less than 50 rpm (e) Pass condition met - (f) ECM selected gear Neutral
ON malfunction (E)
- START CONDITIONS OF J5SUMMAX CALCULATION
Turbine speed 270 rpm or more Neutral state under low torque flag OFF ECM selected gear 5th Time after transition to 5th gear - - when detected abnormal shift 1.5 sec. or more - when not detected abnormal shift Immediately after approval Turbine speed - Output speed x 5th gear ratio 150 rpm or more Output speed More than 0 rpm Calculated input torque when the following conditions are met: (a), (b) and (c) Specified value (a) ECM selected gear 5th (b) Time after transition to 5th gear - - when detected abnormal shift 1.5 sec. or more - when not detected abnormal shift Immediately after approval (c) Turbine speed - Output speed x 5th gear ratio 150 rpm or more FINISH CONDITIONS OF J5SUMMAX CALCULATIONAny of the following conditions are met: (a), (b), (c), (d), (e) or (f) - (a) Turbine speed Less than 270 rpm (b) Neutral state under low torque flag ON (c) ECM selected gear Not 5th (d) Duration time while following condition met 0 sec. or more Turbine speed - Output speed x 5th gear ratio Less than 50 rpm (e) Pass condition met - (f) ECM selected gear Neutral
ON malfunction (F)
- START CONDITIONS OF J6SUMMAX CALCULATION
Turbine speed 270 rpm or more Neutral state under low torque flag OFF ECM selected gear 6th Time after transition to 6th gear - - when detected abnormal shift 1.5 sec. or more - when not detected abnormal shift Immediately after approval Turbine speed - Output speed x 6th gear ratio 150 rpm or more Output speed More than 0 rpm Calculated input torque when the following conditions are met: (a), (b) and (c) Specified value (a) ECM selected gear 6th (b) Time after transition to 6th gear - - when detected abnormal shift 1.5 sec. or more - when not detected abnormal shift Immediately after approval (c) Turbine speed - Output speed x 6th gear ratio 150 rpm or more FINISH CONDITIONS OF J6SUMMAX CALCULATIONAny of the following conditions are met: (a), (b), (c), (d), (e) or (f) - (a) Turbine speed Less than 270 rpm (b) Neutral state under low torque flag ON (c) ECM selected gear Not 6th (d) Duration time while following condition met 0 sec. or more Turbine speed - Output speed x 6th gear ratio Less than 50 rpm (e) Pass condition met - (f) ECM selected gear Neutral
ON malfunction (G)
- START CONDITIONS OF J7SUMMAX CALCULATION
Turbine speed 270 rpm or more Neutral state under low torque flag OFF ECM selected gear 7th Time after transition to 7th gear - - when detected abnormal shift 1.5 sec. or more - when not detected abnormal shift Immediately after approval Turbine speed - Output speed x 7th gear ratio 150 rpm or more Output speed More than 0 rpm Calculated input torque when the following conditions are met: (a), (b) and (c) Specified value (a) ECM selected gear 7th (b) Time after transition to 7th gear - - when detected abnormal shift 1.5 sec. or more - when not detected abnormal shift Immediately after approval (c) Turbine speed - Output speed x 7th gear ratio 150 rpm or more FINISH CONDITIONS OF J7SUMMAX CALCULATIONAny of the following conditions are met: (a), (b), (c), (d), (e) or (f) - (a) Turbine speed Less than 270 rpm (b) Neutral state under low torque flag ON (c) ECM selected gear Not 7th (d) Duration time while following condition met 0 sec. or more Turbine speed - Output speed x 7th gear ratio Less than 50 rpm (e) Pass condition met - (f) ECM selected gear Neutral
ON malfunction (H)
- START CONDITIONS OF J8SUMMAX CALCULATION
Turbine speed 270 rpm or more Neutral state under low torque flag OFF ECM selected gear 8th Time after transition to 8th gear - - when detected abnormal shift 1.5 sec. or more - when not detected abnormal shift Immediately after approval Turbine speed - Output speed x 8th gear ratio 150 rpm or more Output speed More than 0 rpm Calculated input torque when the following conditions are met: (a), (b) and (c) Specified value (a) ECM selected gear 8th (b) Time after transition to 8th gear - - when detected abnormal shift 1.5 sec. or more - when not detected abnormal shift Immediately after approval (c) Turbine speed - Output speed x 8th gear ratio 150 rpm or more FINISH CONDITIONS OF J8SUMMAX CALCULATIONAny of the following conditions are met: (a), (b), (c), (d), (e) or (f) - (a) Turbine speed Less than 270 rpm (b) Neutral state under low torque flag ON (c) ECM selected gear Not 8th (d) Duration time while following condition met 0 sec. or more Turbine speed - Output speed x 8th gear ratio Less than 50 rpm (e) Pass condition met - (f) ECM selected gear Neutral
ON malfunction (J)
ON malfunction (K) and (L)
ON malfunction (N)
ON malfunction (O)
ON malfunction (P)
ON malfunction (Q)
ECM selected gear 1st or 2nd Neutral state flag ON Calculated input torque when Neutral state flag ON Specified value 1st gear pass detection Not fixed (after transition to latest gear) 2nd gear pass detection Not fixed (after transition to latest gear) Output speed x 3rd gear ratio Less than 6500 rpm
ON malfunction (R)
ECM selected gear 3rd, 4th, 6th, 7th or 8th Neutral state flag ON Calculated input torque when Neutral state flag ON Specified value Output speed x 5th gear ratio Less than 6500 rpm - Any of the following conditions are met: condition (a) or (b)CONDITION (A)
ECM selected gear 8th 8th gear pass detection Not fixed (after transition to latest gear) CONDITION (B)Following conditions are met (1) and (((2), (3), (4) and (5)) or (6)) (1) ECM selected gear 3rd, 4th, 6th or 7th (2) 3rd gear pass detection Not fixed (after transition to latest gear) (3) 4th gear pass detection Not fixed (after transition to latest gear) (4) 6th gear pass detection Not fixed (after transition to latest gear) (5) 7th gear pass detection Not fixed (after transition to latest gear) (6) ECM commanded solenoid (SL) valve state OFF (after transition to latest gear) - Any of the following conditions are met: condition (a), (b), (c) or (d)CONDITION (A)
ECM selected gear 4th or 7th Turbine speed - Output speed x 3rd gear ratio More than 50 rpm CONDITION (B)ECM selected gear 6th Turbine speed - Output speed x 4th gear ratio More than 50 rpm CONDITION (C)ECM selected gear 8th Turbine speed - Output speed x 5th gear ratio More than 50 rpm CONDITION (D)ECM selected gear 3rd
- Any of the following conditions are met: condition (a) or (b)
ON malfunction (S)
ECM selected gear 5th Neutral state flag ON Calculated input torque when Neutral state flag ON Specified value 5th gear pass detection Not fixed (after transition to latest gear) Turbine speed - Output speed x 3rd gear ratio More than 50 rpm Output speed x 4th gear ratio Less than 6500 rpm
OFF malfunction
Fail-safe function does not operate due to the following malfunctions: - Solenoid (SL1) valve Not OFF or ON malfunction (P0746) Solenoid (SL2) valve Not OFF or ON malfunction (P0776) Solenoid (SL3) valve Not OFF or ON malfunction (P0796) Solenoid (SL4) valve Not OFF or ON malfunction (P2808) Solenoid (SL5) valve Not OFF or ON malfunction (P2817) Solenoid (SL6) valve Not OFF or ON malfunction (P08BB) Solenoid (SLT) valve Not OFF malfunction (P2714) Solenoid (SLU) valve Not ON malfunction (P2757) Solenoid (SL) valve Not ON malfunction (P0741) All shift solenoids Not being stopped Neutral command flag Not met ECM selected gear 2nd, 3rd, 4th, 6th, 7th or 8th Vehicle speed 2 km/h (1.2 mph) or more Throttle valve opening angle 5% or more at engine speed 2000 rpm
(conditions vary with engine speed)Calculated load value - - When A/C off 16.0% or more - When A/C on 19.0% or more ECT 40°C (104°F) or more Spark advance from MAX. retard timing by KCS control 0 °CA or more
HINT:
NEUTRAL STATE UNDER LOW TORQUE FLAG
| Neutral state flag | ON |
| ECM selected gear | 1st, 2nd, 3rd, 4th, 5th, 6th, 7th or 8th |
| Fail-safe mode flag | OFF |
- Any of the following conditions are met: Condition (a) or (b)
- CONDITION (A)
ECM selected gear 1st, 2nd, 5th or 8th 1st gear pass detection Not fixed (after transition to latest gear) 2nd gear pass detection Not fixed (after transition to latest gear) 5th gear pass detection Not fixed (after transition to latest gear) 8th gear pass detection Not fixed (after transition to latest gear) CONDITION (B)Following conditions are met (1) and (((2), (3), (4) and (5)) or (6)) (1) ECM selected gear 3rd, 4th, 6th or 7th (2) 3rd gear pass detection Not fixed (after transition to latest gear) (3) 4th gear pass detection Not fixed (after transition to latest gear) (4) 6th gear pass detection Not fixed (after transition to latest gear) (5) 7th gear pass detection Not fixed (after transition to latest gear) (6) ECM commanded solenoid (SL) valve state OFF (after transition to latest gear)
- Any of the following conditions are met: Condition (a), (b), (c) or (d)CONDITION (A)
ECM selected gear 4th, 5th or 7th Turbine speed - Output speed x 3rd gear ratio More than 50 rpm CONDITION (B)ECM selected gear 6th Turbine speed - Output speed x 4th gear ratio More than 50 rpm CONDITION (C)ECM selected gear 8th Turbine speed - Output speed x 5th gear ratio More than 50 rpm CONDITION (D)ECM selected gear 1st, 2nd or 3rd
NEUTRAL STATE FLAG:
| Turbine speed - output speed x (ECM selected gear ratio) | 1000 rpm or more |
NEUTRAL COMMAND FLAG:
| Engine speed | 7200 rpm or more |
| Turbine speed | 7200 rpm or more |