Typical Malfunction Thresholds
OFF malfunction
- Any of the following conditions are met: OFF malfunction (A), (B) or (C)OFF MALFUNCTION (A) AND (B)
Neutral state flag ON OFF MALFUNCTION (C)Solenoid (SLT) valve ON malfunction
ON malfunction
- Any of the following conditions are met: ON malfunction (A), (B), (C) or (D)ON MALFUNCTION (A) AND (B)
Any of the following conditions are met (a) or (b) (a) Turbine speed/Output speed (NT/NO) 1.401 or more and 1.581 or less
(When output speed less than 350 rpm)(b) Turbine speed - Output speed x 4th gear ratio -50 rpm or more and 50 rpm or less
(When output speed 350 rpm or more)ON MALFUNCTION (C)Any of the following conditions are met (a) or (b) (a) Turbine speed/Output speed (NT/NO) 0.934 or more and 1.065 or less
(When output speed less than 750 rpm)(b) Turbine speed - Output speed x 6th gear ratio -50 rpm or more and 50 rpm or less
(When output speed 750 rpm or more)ON MALFUNCTION (D)Solenoid (SLT) valve ON malfunction
HINT:
NEUTRAL STATE FLAG:
| Turbine speed - output speed x (ECM selected gear ratio) | 1000 rpm or more |