DTC P0710-11: Transmission Fluid Temperature Sensor "A" Circuit Short To Ground [12/2019 - 10/2022]: Procedure
- READ VALUE USING GTS
- Warm up the engine.
- Read the Data List according to the display on the GTS.
Powertrain > Transmission > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note A/T Oil Temperature No. 1 ATF temperature sensor value Min.: -40°C (-40°F)
Max.: 150°C (302°F)- Approximately 80°C (176°F): After stall speed test
- Equal to ambient temperature: When engine is cold
If value is -40°C (-40°F) or 150°C (302°F), ATF temperature sensor circuit is open or shorted Powertrain > Transmission > Data List
Tester Display A/T Oil Temperature No. 1 Result
Result Proceed to Data List value is normal A Data List value is not normal B
Result:
A
See step 3
Result:
B
See step 2
- CHECK HARNESS AND CONNECTOR (ATF TEMPERATURE SENSOR - ECM)
- Disconnect the C54 ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition C54-86 (THO1) - C54-133 (ETHW) Always 79 Ω to 156 kΩ C54-133 (ETHW) - Body ground Always 10 kΩ or higher C54-86 (THO1) - Body ground Always 10 kΩ or higher HINT:
If the resistance is out of the specified range at any of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.
ATF Temperature Specified Condition 10°C (50°F) 5 to 8 kΩ 25°C (77°F) 2.5 to 4.5 kΩ 110°C (230°F) 0.22 to 0.28 kΩ Result
Proceed to OK NG
Result:
NG
See step 4
Result:
OK
See step 3
- REPLACE ECM
- Replace the ECM.
Refer to COMPONENTS [12/2019 - 10/2022]
Result
Proceed to NEXT
Result:
NEXT
PERFORM REGISTRATION. Refer to REGISTRATION [12/2019 - 10/2022]
- Replace the ECM.
- CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
- Disconnect the C51 transmission wire connector.
- Disconnect the C54 ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition C51-1 (OT+) or C54-86 (THO1) - Body ground Always 10 kΩ or higher C51-2 (OT-) or C54-133 (ETHW) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE TRANSMISSION WIRE (ATF TEMPERATURE SENSOR). Refer to COMPONENTS [12/2019 - 10/2022]
Result:
NG