Odo/Trip Switch Malfunction [12/2019 - ]: Procedure
- READ VALUE USING GTS
- Read the Data List according to the display on the GTS.
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note ODO/TRIP Change Switch ODO/TRIP switch OFF or ON OFF: Switch released
ON: Switch pushedWhen the switch is built into the combination meter assembly or is connected via direct line, the input value is displayed. Body Electrical > Combination Meter > Data List
Tester Display ODO/TRIP Change Switch OK
ODO/TRIP switch condition displayed on the GTS changes with the actual switch operation.
Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [12/2019 - ]
Result:
NG
See step 2
- Read the Data List according to the display on the GTS.
- INSPECT TRIP SWITCH
- Remove the trip switch.
Refer to REMOVAL [12/2019 - ]
- Inspect the trip switch.
Refer to INSPECTION [12/2019 - ]
Result
Proceed to OK NG
Result:
NG
REPLACE TRIP SWITCH. Refer to REMOVAL [12/2019 - ]
Result:
OK
See step 3
- Remove the trip switch.
- CHECK HARNESS AND CONNECTOR (TRIP SWITCH - COMBINATION METER ASSEMBLY)
- Disconnect the H22 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition H23-3 (A/B) - H22-1 (ODO) Always Below 1 Ω H23-1 (E) - H22-5 (SW3) Always Below 1 Ω H23-3 (A/B) or H22-1 (ODO) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [12/2019 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR