Typical Malfunction Thresholds
WARNING: This page is about a different variant/trim than selected.
C14C7 (CASE 1)
| IGR voltage | 9.5 V or less |
C14C7 (CASE 3)
| All of the following conditions are met | - |
| Brake system voltage 1 | 7.3 V or less |
| Stroke sensor 1 data validity | Invalid |
| Stroke sensor output compare validity | Invalid |
C14C7 (CASE 4)
| Both of the following conditions are met | - |
| Brake system voltage 1 | 8.5 V or less |
| Reaction force pressure sensor data valid | Invalid |
C14C7 (CASE 5 AND 7)
| Both of the following conditions are met | - |
| Brake system voltage 1 | 8.5 V or less |
| Pressure sensor power supply voltage | 6.5 V or less |
C14C7 (CASE 6)
| Both of the following conditions are met | - |
| Brake system voltage 1 | 8.5 V or less |
| Servo pressure sensor data valid | Invalid |
C14C7 (CASE 8)
| Either of the following conditions is met | A or B |
| A. All of the following conditions are met | - |
| Ready state | Off |
| BS monitor voltage | Less than 3.3 V |
| Brake system voltage 1 | 7.3 V or less |
| Main relay on experience | On |
| B. All of the following conditions are met | - |
| Ready state | On |
| BS monitor voltage | Less than 3.3 V |
| Brake system voltage 1 | 7.3 V or less |
| IGR voltage | 9.5 V or less |
| Main relay on experience | On |
C14C7 (CASE 9)
| Both of the following conditions are met | - |
| Brake system voltage 1 | 8.5 V or less |
| Accumulator pressure sensor data valid | Invalid |