Component Operating Range
WARNING: This page is about a different variant/trim than selected.
ALL
| All of the following conditions are met | A, B, C and D |
| A. Command to brake pressure control solenoid power supply relay | On |
| B. Following condition is met | 0.198 seconds or more |
| Brake system voltage 1 | Higher than 8.5 V |
| C. Power supply for brake pressure control solenoid | Higher than 9.4 V |
| D. Either of the following conditions is met | a or b |
| a. Ignition switch | Off |
| b. Both of the following conditions are met | - |
| Ignition switch | On (READY) |
| IGR voltage | Higher than 9.5 V |