Typical Enabling Conditions
WARNING: This page is about a different variant/trim than selected.
C12E9 (CASE 1)
| Monitor runs whenever the following DTCs are not stored | C0597 (Case 1): ABS hold solenoid circuit stuck C0597 (Case 2 to 5): ABS hold solenoid performance C12A7: ABS hold solenoid (FL) circuit low C12A8: ABS hold solenoid (FL) circuit high C12B2: ABS release solenoid (FL) circuit low C12B3: ABS release solenoid (FL) circuit high C12BD: ABS hold solenoid (FR) circuit low C12BE: ABS hold solenoid (FR) circuit high C12C8: ABS release solenoid (FR) circuit low C12C9: ABS release solenoid (FR) circuit high C12D3: ABS hold solenoid (RL) circuit low C12D4: ABS hold solenoid (RL) circuit high C12DE: ABS release solenoid (RL) circuit low C12DF: ABS release solenoid (RL) circuit high C12EA: ABS hold solenoid (RR) circuit high C12F4: ABS release solenoid (RR) circuit low C12F5: ABS release solenoid (RR) circuit high C12F6: ABS hold solenoid other functional C12F7: ABS hold solenoid other functional C137C: Brake system voltage input out of range low C137D: Brake system voltage input out of range high C13BF: SM solenoid other functional C13C2: SM1 solenoid circuit low C13C3: SM1 solenoid circuit high C13CB: SM2 solenoid circuit low C13CC: SM2 solenoid circuit high C143B: Brake system voltage solenoid relay stuck C143C: Brake system voltage open circuit |
| All of the following conditions are met | A, B, C and D |
| A. Command to solenoid relay | On |
| B. Power supply for solenoid | Higher than 6 V |
| C. +BS voltage | 17.4 V or less |
| D. Following condition is met | 0.054 seconds or more |
| ABS hold solenoid target current value | 0 A |
C12E9 (CASE 2)
| Monitor runs whenever the following DTCs are not stored | C0597 (Case 1): ABS hold solenoid circuit stuck C0597 (Case 2 to 5): ABS hold solenoid performance C12A7: ABS hold solenoid (FL) circuit low C12A8: ABS hold solenoid (FL) circuit high C12B2: ABS release solenoid (FL) circuit low C12B3: ABS release solenoid (FL) circuit high C12BD: ABS hold solenoid (FR) circuit low C12BE: ABS hold solenoid (FR) circuit high C12C8: ABS release solenoid (FR) circuit low C12C9: ABS release solenoid (FR) circuit high C12D3: ABS hold solenoid (RL) circuit low C12D4: ABS hold solenoid (RL) circuit high C12DE: ABS release solenoid (RL) circuit low C12DF: ABS release solenoid (RL) circuit high C12EA: ABS hold solenoid (RR) circuit high C12F4: ABS release solenoid (RR) circuit low C12F5: ABS release solenoid (RR) circuit high C12F6: ABS hold solenoid other functional C12F7: ABS hold solenoid other functional C137C: Brake system voltage input out of range low C137D: Brake system voltage input out of range high C13BF: SM solenoid other functional C13C2: SM1 solenoid circuit low C13C3: SM1 solenoid circuit high C13CB: SM2 solenoid circuit low C13CC: SM2 solenoid circuit high C143B: Brake system voltage solenoid relay stuck C143C: Brake system voltage open circuit |
| All of the following conditions are met | - |
| Command to solenoid relay | On |
| Power supply for solenoid | Higher than 6 V |
| +BS voltage | 17.4 V or less |
C12E9 (CASE 3)
| Monitor runs whenever the following DTCs are not stored | C0597 (Case 1): ABS hold solenoid circuit stuck C0597 (Case 2 to 5): ABS hold solenoid performance C12A7: ABS hold solenoid (FL) circuit low C12A8: ABS hold solenoid (FL) circuit high C12B2: ABS release solenoid (FL) circuit low C12B3: ABS release solenoid (FL) circuit high C12BD: ABS hold solenoid (FR) circuit low C12BE: ABS hold solenoid (FR) circuit high C12C8: ABS release solenoid (FR) circuit low C12C9: ABS release solenoid (FR) circuit high C12D3: ABS hold solenoid (RL) circuit low C12D4: ABS hold solenoid (RL) circuit high C12DE: ABS release solenoid (RL) circuit low C12DF: ABS release solenoid (RL) circuit high C12EA: ABS hold solenoid (RR) circuit high C12F4: ABS release solenoid (RR) circuit low C12F5: ABS release solenoid (RR) circuit high C12F6: ABS hold solenoid other functional C12F7: ABS hold solenoid other functional C137C: Brake system voltage input out of range low C137D: Brake system voltage input out of range high C13BF: SM solenoid other functional C13C2: SM1 solenoid circuit low C13C3: SM1 solenoid circuit high C13CB: SM2 solenoid circuit low C13CC: SM2 solenoid circuit high C143B: Brake system voltage solenoid relay stuck C143C: Brake system voltage open circuit |
| All of the following conditions are met | A, B, C, D, E, F, G and H |
| A. Command to solenoid relay | On |
| B. +BS voltage | 17.4 V or less |
| C. Power supply for solenoid | 9.5 V or more |
| D. Following condition is met | 0.048 seconds or more |
| ABS hold solenoid target current value | 0.25 A or more |
| E. Solenoid overcurrent signal | Off |
| F. Solenoid driver overtemperature signal | Off |
| G. Solenoid return current terminal disconnection signal | Off |
| H. Solenoid GND terminal disconnection signal | Off |
C12EA (CASE 1)
| Monitor runs whenever the following DTCs are not stored | C0597 (Case 1): ABS hold solenoid circuit stuck C0597 (Case 2 to 5): ABS hold solenoid performance C12A7: ABS hold solenoid (FL) circuit low C12A8: ABS hold solenoid (FL) circuit high C12B2: ABS release solenoid (FL) circuit low C12B3: ABS release solenoid (FL) circuit high C12BD: ABS hold solenoid (FR) circuit low C12BE: ABS hold solenoid (FR) circuit high C12C8: ABS release solenoid (FR) circuit low C12C9: ABS release solenoid (FR) circuit high C12D3: ABS hold solenoid (RL) circuit low C12D4: ABS hold solenoid (RL) circuit high C12DE: ABS release solenoid (RL) circuit low C12DF: ABS release solenoid (RL) circuit high C12E9: ABS hold solenoid (RR) circuit low C12F4: ABS release solenoid (RR) circuit low C12F5: ABS release solenoid (RR) circuit high C12F6: ABS hold solenoid other functional C12F7: ABS hold solenoid other functional C137C: Brake system voltage input out of range low C137D: Brake system voltage input out of range high C13BF: SM solenoid other functional C13C2: SM1 solenoid circuit low C13C3: SM1 solenoid circuit high C13CB: SM2 solenoid circuit low C13CC: SM2 solenoid circuit high C143B: Brake system voltage solenoid relay stuck C143C: Brake system voltage open circuit |
| All of the following conditions are met | A, B, C, D, E, F, G, H, I and J |
| A. Command to solenoid relay | On |
| B. Power supply for solenoid | Higher than 6 V |
| C. +BS voltage | 17.4 V or less |
| D. Following condition is met | 0.054 seconds or more |
| ABS hold solenoid target current value | 0 A |
| E. Solenoid overcurrent signal | Off |
| F. Solenoid driver overtemperature signal | Off |
| G. Solenoid load open/short to ground signal | Off |
| H. Solenoid load leakage signal | Off |
| I. Solenoid return current terminal disconnection signal | Off |
| J. Solenoid GND terminal disconnection signal | Off |
C12EA (CASE 2)
| Monitor runs whenever the following DTCs are not stored | C0597 (Case 1): ABS hold solenoid circuit stuck C0597 (Case 2 to 5): ABS hold solenoid performance C12A7: ABS hold solenoid (FL) circuit low C12A8: ABS hold solenoid (FL) circuit high C12B2: ABS release solenoid (FL) circuit low C12B3: ABS release solenoid (FL) circuit high C12BD: ABS hold solenoid (FR) circuit low C12BE: ABS hold solenoid (FR) circuit high C12C8: ABS release solenoid (FR) circuit low C12C9: ABS release solenoid (FR) circuit high C12D3: ABS hold solenoid (RL) circuit low C12D4: ABS hold solenoid (RL) circuit high C12DE: ABS release solenoid (RL) circuit low C12DF: ABS release solenoid (RL) circuit high C12E9: ABS hold solenoid (RR) circuit low C12F4: ABS release solenoid (RR) circuit low C12F5: ABS release solenoid (RR) circuit high C12F6: ABS hold solenoid other functional C12F7: ABS hold solenoid other functional C137C: Brake system voltage input out of range low C137D: Brake system voltage input out of range high C13BF: SM solenoid other functional C13C2: SM1 solenoid circuit low C13C3: SM1 solenoid circuit high C13CB: SM2 solenoid circuit low C13CC: SM2 solenoid circuit high C143B: Brake system voltage solenoid relay stuck C143C: Brake system voltage open circuit |
| All of the following conditions are met | - |
| Command to solenoid relay | On |
| Power supply for solenoid | Higher than 6 V |
| +BS voltage | 17.4 V or less |
C12EA (CASE 3)
| Monitor runs whenever the following DTCs are not stored | C0597 (Case 1): ABS hold solenoid circuit stuck C0597 (Case 2 to 5): ABS hold solenoid performance C12A7: ABS hold solenoid (FL) circuit low C12A8: ABS hold solenoid (FL) circuit high C12B2: ABS release solenoid (FL) circuit low C12B3: ABS release solenoid (FL) circuit high C12BD: ABS hold solenoid (FR) circuit low C12BE: ABS hold solenoid (FR) circuit high C12C8: ABS release solenoid (FR) circuit low C12C9: ABS release solenoid (FR) circuit high C12D3: ABS hold solenoid (RL) circuit low C12D4: ABS hold solenoid (RL) circuit high C12DE: ABS release solenoid (RL) circuit low C12DF: ABS release solenoid (RL) circuit high C12E9: ABS hold solenoid (RR) circuit low C12F4: ABS release solenoid (RR) circuit low C12F5: ABS release solenoid (RR) circuit high C12F6: ABS hold solenoid other functional C12F7: ABS hold solenoid other functional C137C: Brake system voltage input out of range low C137D: Brake system voltage input out of range high C13BF: SM solenoid other functional C13C2: SM1 solenoid circuit low C13C3: SM1 solenoid circuit high C13CB: SM2 solenoid circuit low C13CC: SM2 solenoid circuit high C143B: Brake system voltage solenoid relay stuck C143C: Brake system voltage open circuit |
| All of the following conditions are met | A, B, C, D and E |
| A. Command to solenoid relay | On |
| B. Power supply for solenoid | Higher than 6 V |
| C. +BS voltage | 17.4 V or less |
| D. Following condition is met | 0.054 seconds or more |
| ABS hold solenoid target current value | 0 A |
| E. Solenoid load open/short to ground signal | Off |
C12EA (CASE 4)
| Monitor runs whenever the following DTCs are not stored | C0597 (Case 1): ABS hold solenoid circuit stuck C0597 (Case 2 to 5): ABS hold solenoid performance C12A7: ABS hold solenoid (FL) circuit low C12A8: ABS hold solenoid (FL) circuit high C12B2: ABS release solenoid (FL) circuit low C12B3: ABS release solenoid (FL) circuit high C12BD: ABS hold solenoid (FR) circuit low C12BE: ABS hold solenoid (FR) circuit high C12C8: ABS release solenoid (FR) circuit low C12C9: ABS release solenoid (FR) circuit high C12D3: ABS hold solenoid (RL) circuit low C12D4: ABS hold solenoid (RL) circuit high C12DE: ABS release solenoid (RL) circuit low C12DF: ABS release solenoid (RL) circuit high C12E9: ABS hold solenoid (RR) circuit low C12F4: ABS release solenoid (RR) circuit low C12F5: ABS release solenoid (RR) circuit high C12F6: ABS hold solenoid other functional C12F7: ABS hold solenoid other functional C137C: Brake system voltage input out of range low C137D: Brake system voltage input out of range high C13BF: SM solenoid other functional C13C2: SM1 solenoid circuit low C13C3: SM1 solenoid circuit high C13CB: SM2 solenoid circuit low C13CC: SM2 solenoid circuit high C143B: Brake system voltage solenoid relay stuck C143C: Brake system voltage open circuit |
| All of the following conditions are met | A, B, C, D, E, F, G and H |
| A. Command to solenoid relay | On |
| B. +BS voltage | 17.4 V or less |
| C. Power supply for solenoid | 9.5 V or more |
| D. Following condition is met | 0.048 seconds or more |
| ABS hold solenoid target current value | Higher than 0 A |
| E. Solenoid overcurrent signal | Off |
| F. Solenoid driver overtemperature signal | Off |
| G. Solenoid return current terminal disconnection signal | Off |
| H. Solenoid GND terminal disconnection signal | Off |
C12F4 (CASE 1)
| Monitor runs whenever the following DTCs are not stored | C0597 (Case 1): ABS hold solenoid circuit stuck C0597 (Case 2 to 5): ABS hold solenoid performance C12A7: ABS hold solenoid (FL) circuit low C12A8: ABS hold solenoid (FL) circuit high C12B2: ABS release solenoid (FL) circuit low C12B3: ABS release solenoid (FL) circuit high C12BD: ABS hold solenoid (FR) circuit low C12BE: ABS hold solenoid (FR) circuit high C12C8: ABS release solenoid (FR) circuit low C12C9: ABS release solenoid (FR) circuit high C12D3: ABS hold solenoid (RL) circuit low C12D4: ABS hold solenoid (RL) circuit high C12DE: ABS release solenoid (RL) circuit low C12DF: ABS release solenoid (RL) circuit high C12E9: ABS hold solenoid (RR) circuit low C12EA: ABS hold solenoid (RR) circuit high C12F5: ABS release solenoid (RR) circuit high C12F6: ABS hold solenoid other functional C12F7: ABS hold solenoid other functional C137C: Brake system voltage input out of range low C137D: Brake system voltage input out of range high C13BF: SM solenoid other functional C13C2: SM1 solenoid circuit low C13C3: SM1 solenoid circuit high C13CB: SM2 solenoid circuit low C13CC: SM2 solenoid circuit high C143B: Brake system voltage solenoid relay stuck C143C: Brake system voltage open circuit |
| All of the following conditions are met | A, B, C and D |
| A. Command to solenoid relay | On |
| B. Power supply for solenoid | Higher than 6 V |
| C. +BS voltage | 17.4 V or less |
| D. Both of the following conditions are met | a and b |
| a. Following condition is met | 0.015 seconds or more |
| Command to ABS release solenoid | Off |
| b. Either of the following conditions is met | 1 or 2 |
| 1. Following condition is met | 0.015 seconds or more |
| Command to reference solenoid | Off |
| 2. Following condition is met | 0.006 seconds or more |
| Command to reference solenoid | On |
C12F4 (CASE 2)
| Monitor runs whenever the following DTCs are not stored | C0597 (Case 1): ABS hold solenoid circuit stuck C0597 (Case 2 to 5): ABS hold solenoid performance C12A7: ABS hold solenoid (FL) circuit low C12A8: ABS hold solenoid (FL) circuit high C12B2: ABS release solenoid (FL) circuit low C12B3: ABS release solenoid (FL) circuit high C12BD: ABS hold solenoid (FR) circuit low C12BE: ABS hold solenoid (FR) circuit high C12C8: ABS release solenoid (FR) circuit low C12C9: ABS release solenoid (FR) circuit high C12D3: ABS hold solenoid (RL) circuit low C12D4: ABS hold solenoid (RL) circuit high C12DE: ABS release solenoid (RL) circuit low C12DF: ABS release solenoid (RL) circuit high C12E9: ABS hold solenoid (RR) circuit low C12EA: ABS hold solenoid (RR) circuit high C12F5: ABS release solenoid (RR) circuit high C12F6: ABS hold solenoid other functional C12F7: ABS hold solenoid other functional C137C: Brake system voltage input out of range low C137D: Brake system voltage input out of range high C13BF: SM solenoid other functional C13C2: SM1 solenoid circuit low C13C3: SM1 solenoid circuit high C13CB: SM2 solenoid circuit low C13CC: SM2 solenoid circuit high C143B: Brake system voltage solenoid relay stuck C143C: Brake system voltage open circuit |
| All of the following conditions are met | A, B, C and D |
| A. Command to solenoid relay | On |
| B. Power supply for solenoid | Higher than 6 V |
| C. +BS voltage | 17.4 V or less |
| D. Both of the following conditions are met | a and b |
| a. Either of the following conditions is met | 1 or 2 |
| 1. Following condition is met | 0.015 seconds or more |
| Command to ABS release solenoid | Off |
| 2. Following condition is met | 0.006 seconds or more |
| Command to ABS release solenoid | On |
| b. Either of the following conditions is met | 1 or 2 |
| 1. Following condition is met | 0.015 seconds or more |
| Command to reference solenoid | Off |
| 2. Following condition is met | 0.006 seconds or more |
| Command to reference solenoid | On |
C12F5 (CASE 1)
| Monitor runs whenever the following DTCs are not stored | C0597 (Case 1): ABS hold solenoid circuit stuck C0597 (Case 2 to 5): ABS hold solenoid performance C12A7: ABS hold solenoid (FL) circuit low C12A8: ABS hold solenoid (FL) circuit high C12B2: ABS release solenoid (FL) circuit low C12B3: ABS release solenoid (FL) circuit high C12BD: ABS hold solenoid (FR) circuit low C12BE: ABS hold solenoid (FR) circuit high C12C8: ABS release solenoid (FR) circuit low C12C9: ABS release solenoid (FR) circuit high C12D3: ABS hold solenoid (RL) circuit low C12D4: ABS hold solenoid (RL) circuit high C12DE: ABS release solenoid (RL) circuit low C12DF: ABS release solenoid (RL) circuit high C12E9: ABS hold solenoid (RR) circuit low C12EA: ABS hold solenoid (RR) circuit high C12F4: ABS release solenoid (RR) circuit low C12F6: ABS hold solenoid other functional C12F7: ABS hold solenoid other functional C137C: Brake system voltage input out of range low C137D: Brake system voltage input out of range high C13BF: SM solenoid other functional C13C2: SM1 solenoid circuit low C13C3: SM1 solenoid circuit high C13CB: SM2 solenoid circuit low C13CC: SM2 solenoid circuit high C143B: Brake system voltage solenoid relay stuck C143C: Brake system voltage open circuit |
| All of the following conditions are met | A, B, C and D |
| A. Command to solenoid relay | On |
| B. Power supply for solenoid | Higher than 6 V |
| C. +BS voltage | 17.4 V or less |
| D. Both of the following conditions are met | a and b |
| a. Either of the following conditions is met | 1 or 2 |
| 1. Following condition is met | 0.015 seconds or more |
| Command to ABS release solenoid | Off |
| 2. Following condition is met | 0.006 seconds or more |
| Command to ABS release solenoid | On |
| b. Either of the following conditions is met | 1 or 2 |
| 1. Following condition is met | 0.015 seconds or more |
| Command to reference solenoid | Off |
| 2. Following condition is met | 0.006 seconds or more |
| Command to reference solenoid | On |
C12F5 (CASE 2)
| Monitor runs whenever the following DTCs are not stored | C0597 (Case 1): ABS hold solenoid circuit stuck C0597 (Case 2 to 5): ABS hold solenoid performance C12A7: ABS hold solenoid (FL) circuit low C12A8: ABS hold solenoid (FL) circuit high C12B2: ABS release solenoid (FL) circuit low C12B3: ABS release solenoid (FL) circuit high C12BD: ABS hold solenoid (FR) circuit low C12BE: ABS hold solenoid (FR) circuit high C12C8: ABS release solenoid (FR) circuit low C12C9: ABS release solenoid (FR) circuit high C12D3: ABS hold solenoid (RL) circuit low C12D4: ABS hold solenoid (RL) circuit high C12DE: ABS release solenoid (RL) circuit low C12DF: ABS release solenoid (RL) circuit high C12E9: ABS hold solenoid (RR) circuit low C12EA: ABS hold solenoid (RR) circuit high C12F4: ABS release solenoid (RR) circuit low C12F6: ABS hold solenoid other functional C12F7: ABS hold solenoid other functional C137C: Brake system voltage input out of range low C137D: Brake system voltage input out of range high C13BF: SM solenoid other functional C13C2: SM1 solenoid circuit low C13C3: SM1 solenoid circuit high C13CB: SM2 solenoid circuit low C13CC: SM2 solenoid circuit high C143B: Brake system voltage solenoid relay stuck C143C: Brake system voltage open circuit |
| All of the following conditions are met | A, B, C, D and E |
| A. Command to solenoid relay | On |
| B. Power supply for solenoid | Higher than 6 V |
| C. +BS voltage | 17.4 V or less |
| D. Both of the following conditions are met | a and b |
| a. Either of the following conditions is met | 1 or 2 |
| 1. Following condition is met | 0.015 seconds or more |
| Command to ABS release solenoid | Off |
| 2. Following condition is met | 0.006 seconds or more |
| Command to ABS release solenoid | On |
| b. Either of the following conditions is met | 1 or 2 |
| 1. Following condition is met | 0.015 seconds or more |
| Command to reference solenoid | Off |
| 2. Following condition is met | 0.006 seconds or more |
| Command to reference solenoid | On |
| E. Solenoid load open/short to ground signal | Off |