Typical Enabling Conditions
WARNING: This page is about a different variant/trim than selected.
C12FA (CASE 1)
| Monitor runs whenever the following DTCs are not stored | C14C7 (Case 3 to 9): Brake system voltage circuit low |
| All of the following conditions are met | A, B, C and D |
| A. Ignition switch | Off |
| B. +BS (linear) effective invalidity | Valid |
| C. Command to brake pressure control solenoid power supply relay | On |
| D. Either of the following conditions is met | - |
| Brake system voltage 1 | Higher than 7.3 V |
| Main relay on experience | Unavailable |
C12FA (CASE 2)
| Monitor runs whenever the following DTCs are not stored | C14C7 (Case 3 to 9): Brake system voltage circuit low |
| All of the following conditions are met | A, B, C and D |
| A. Ignition switch | On (READY) |
| B. +BS (linear) effective invalidity | Valid |
| C. Command to brake pressure control solenoid power supply relay | On |
| D. Either of the following conditions is met | a or b |
| a. Both of the following conditions are met | - |
| Brake system voltage 1 | Higher than 7.3 V |
| IGR voltage | Higher than 9.5 V |
| b. Main relay on experience | Unavailable |
C12FA (CASE 3)
| Monitor runs whenever the following DTCs are not stored | C14C7 (Case 3 to 9): Brake system voltage circuit low |
| Both of the following conditions are met | - |
| Solenoid relay | On |
| Brake system voltage 1 | Higher than 7.3 V |
C12FB (CASE 1)
| Monitor runs whenever the following DTCs are not stored | None |
| Both of the following conditions are met | - |
| +BS (linear) effective invalidity | Valid |
| Command to brake pressure control solenoid power supply relay | Off |
C12FB (CASE 2)
| Monitor runs whenever the following DTCs are not stored | None |
| Solenoid relay | Off |