Typical Enabling Conditions
WARNING: This page is about a different variant/trim than selected.
C121F (CASE 1)
| Monitor runs whenever the following DTCs are not stored | C14C7 (Case 3 to 9): Brake system voltage circuit low C14C8: Brake system voltage circuit high |
| Brake system voltage 1 | Higher than 7.3 V and less than 16.6 V |
C121F (CASE 2)
| Monitor runs whenever the following DTCs are not stored | C14C7 (Case 3 to 9): Brake system voltage circuit low C14C8: Brake system voltage circuit high |
| All of the following conditions are met | - |
| Solenoid relay | Off |
| ASIC output permission | Off |
| ASIC send data | NG answer |
C14F3 (CASE 1)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | A, B, C and D |
| A. Command to main relay | On |
| B. Power supply for solenoid voltage | Higher than 6.0 V |
| C. Brake system voltage 1 | Less than 17.4 V |
| D. Following condition is met | 0.033 seconds or more |
| Brake pressure control solenoid target current value | 0 A |
C14F3 (CASE 2 AND 4)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| Both of the following conditions are met | - |
| Power supply for solenoid voltage | 6.0 V or more |
| Solenoid relay | On |
C14F3 (CASE 3)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | - |
| Command to main relay | On |
| Power supply for solenoid voltage | Higher than 6.0 V |
| Brake system voltage 1 | Less than 17.4 V |
C14F3 (CASE 5)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | A, B, C, D, E, F, G and H |
| A. Command to main relay | On |
| B. Power supply for solenoid voltage | 9.5 V or more |
| C. Brake system voltage 1 | Less than 17.4 V |
| D. Following condition is met | 0.012 seconds or more |
| Brake pressure control solenoid target current value | 0.348 A |
| E. Solenoid over current signal | Off |
| F. Solenoid driver overtemperature signal | Off |
| G. Solenoid return current terminal disconnection signal | Off |
| H. Solenoid GND terminal disconnection signal | Off |
C14F3 (CASE 6)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| Solenoid current output order value | 150.00 mA |
C14F4 (CASE 1)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | A, B, C, D, E, F, G, H, I and J |
| A. Command to main relay | On |
| B. Power supply for solenoid voltage | Higher than 6.0 V |
| C. Brake system voltage 1 | Less than 17.4 V |
| D. Following condition is met | 0.033 seconds or more |
| Brake pressure control solenoid target current value | 0 A |
| E. Solenoid over current signal | Off |
| F. Solenoid driver overtemperature signal | Off |
| G. Solenoid load open/short to ground signal | Off |
| H. Solenoid load leakage signal | Off |
| I. Solenoid return current terminal disconnection signal | Off |
| J. Solenoid GND terminal disconnection signal | Off |
C14F4 (CASE 2)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| Both of the following conditions are met | - |
| Brake system voltage 1 | Higher than 7.3 V |
| Solenoid current output order value | 0.70 mA |
C14F4 (CASE 3)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | - |
| Command to main relay | On |
| Power supply for solenoid voltage | Higher than 6.0 V |
| Brake system voltage 1 | Less than 17.4 V |
C14F4 (CASE 4 AND 6)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| Both of the following conditions are met | - |
| Power supply for solenoid voltage | 6.0 V or more |
| Solenoid relay | On |
C14F4 (CASE 5)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | A, B, C, D and E |
| A. Command to main relay | On |
| B. Power supply for solenoid voltage | Higher than 6.0 V |
| C. Brake system voltage 1 | Less than 17.4 V |
| D. Following condition is met | 0.033 seconds or more |
| Brake pressure control solenoid target current value | 0 A |
| E. Solenoid load open/short to ground signal | Off |
C14F4 (CASE 7)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | A, B, C, D, E, F, G and H |
| A. Command to main relay | On |
| B. Power supply for solenoid voltage | 9.5 V or more |
| C. Brake system voltage 1 | Less than 17.4 V |
| D. Following condition is met | 0.033 seconds or more |
| Brake pressure control solenoid target current value | 0 A |
| E. Solenoid over current signal | Off |
| F. Solenoid driver overtemperature signal | Off |
| G. Solenoid return current terminal disconnection signal | Off |
| H. Solenoid GND terminal disconnection signal | Off |
C14F4 (CASE 8)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| Solenoid current output order value | 150.00 mA |
C14FC (CASE 1)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | A, B, C and D |
| A. Command to main relay | On |
| B. Power supply for solenoid voltage | Higher than 6.0 V |
| C. Brake system voltage 1 | Less than 17.4 V |
| D. Following condition is met | 0.033 seconds or more |
| Brake pressure control solenoid target current value | 0 A |
C14FC (CASE 2 AND 4)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| Both of the following conditions are met | - |
| Power supply for solenoid voltage | 6.0 V or more |
| Solenoid relay | On |
C14FC (CASE 3)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | - |
| Command to main relay | On |
| Power supply for solenoid voltage | Higher than 6.0 V |
| Brake system voltage 1 | Less than 17.4 V |
C14FC (CASE 5)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | A, B, C, D, E, F, G and H |
| A. Command to main relay | On |
| B. Power supply for solenoid voltage | 9.5 V or more |
| C. Brake system voltage 1 | Less than 17.4 V |
| D. Following condition is met | 0.012 seconds or more |
| Brake pressure control solenoid target current value | 0.348 A |
| E. Solenoid over current signal | Off |
| F. Solenoid driver overtemperature signal | Off |
| G. Solenoid return current terminal disconnection signal | Off |
| H. Solenoid GND terminal disconnection signal | Off |
C14FC (CASE 6)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| Solenoid current output order value | 150.00 mA |
C14FD (CASE 1)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | A, B, C, D, E, F, G, H, I and J |
| A. Command to main relay | On |
| B. Power supply for solenoid voltage | Higher than 6.0 V |
| C. Brake system voltage 1 | Less than 17.4 V |
| D. Following condition is met | 0.033 seconds or more |
| Brake pressure control solenoid target current value | 0 A |
| E. Solenoid over current signal | Off |
| F. Solenoid driver overtemperature signal | Off |
| G. Solenoid load open/short to ground signal | Off |
| H. Solenoid load leakage signal | Off |
| I. Solenoid return current terminal disconnection signal | Off |
| J. Solenoid GND terminal disconnection signal | Off |
C14FD (CASE 2)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| Both of the following conditions are met | - |
| Brake system voltage 1 | Higher than 7.3 V |
| Solenoid current output order value | 0.70 mA |
C14FD (CASE 3)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | - |
| Command to main relay | On |
| Power supply for solenoid voltage | Higher than 6.0 V |
| Brake system voltage 1 | Less than 17.4 V |
C14FD (CASE 4 AND 6)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| Both of the following conditions are met | - |
| Power supply for solenoid voltage | 6.0 V or more |
| Solenoid relay | On |
C14FD (CASE 5)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | A, B, C, D and E |
| A. Command to main relay | On |
| B. Power supply for solenoid voltage | Higher than 6.0 V |
| C. Brake system voltage 1 | Less than 17.4 V |
| D. Following condition is met | 0.033 seconds or more |
| Brake pressure control solenoid target current value | 0 A |
| E. Solenoid load open/short to ground signal | Off |
C14FD (CASE 7)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | A, B, C, D, E, F, G and H |
| A. Command to main relay | On |
| B. Power supply for solenoid voltage | 9.5 V or more |
| C. Brake system voltage 1 | Less than 17.4 V |
| D. Following condition is met | 0.033 seconds or more |
| Brake pressure control solenoid target current value | 0 A |
| E. Solenoid over current signal | Off |
| F. Solenoid driver overtemperature signal | Off |
| G. Solenoid return current terminal disconnection signal | Off |
| H. Solenoid GND terminal disconnection signal | Off |
C14FD (CASE 8)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| Solenoid current output order value | 150.00 mA |
C1509 (CASE 1)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | A, B, C and D |
| A. Command to main relay | On |
| B. Power supply for solenoid voltage | Higher than 6.0 V |
| C. Brake system voltage 1 | Less than 17.4 V |
| D. Following condition is met | 0.033 seconds or more |
| Brake pressure control solenoid target current value | 0 A |
C1509 (CASE 2 AND 4)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| Both of the following conditions are met | - |
| Power supply for solenoid voltage | 6.0 V or more |
| Solenoid relay | On |
C1509 (CASE 3)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | - |
| Command to main relay | On |
| Power supply for solenoid voltage | Higher than 6.0 V |
| Brake system voltage 1 | Less than 17.4 V |
C1509 (CASE 5)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | A, B, C, D, E, F, G and H |
| A. Command to main relay | On |
| B. Power supply for solenoid voltage | 9.5 V or more |
| C. Brake system voltage 1 | Less than 17.4 V |
| D. Following condition is met | 0.012 seconds or more |
| Brake pressure control solenoid target current value | 0.348 A |
| E. Solenoid over current signal | Off |
| F. Solenoid driver overtemperature signal | Off |
| G. Solenoid return current terminal disconnection signal | Off |
| H. Solenoid GND terminal disconnection signal | Off |
C1509 (CASE 6)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| Solenoid current output order value | 150.00 mA |
C150A (CASE 1)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | A, B, C, D, E, F, G, H, I and J |
| A. Command to main relay | On |
| B. Power supply for solenoid voltage | Higher than 6.0 V |
| C. Brake system voltage 1 | Less than 17.4 V |
| D. Following condition is met | 0.033 seconds or more |
| Brake pressure control solenoid target current value | 0 A |
| E. Solenoid over current signal | Off |
| F. Solenoid driver overtemperature signal | Off |
| G. Solenoid load open/short to ground signal | Off |
| H. Solenoid load leakage signal | Off |
| I. Solenoid return current terminal disconnection signal | Off |
| J. Solenoid GND terminal disconnection signal | Off |
C150A (CASE 2)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| Both of the following conditions are met | - |
| Brake system voltage 1 | Higher than 7.3 V |
| Solenoid current output order value | 0.70 mA |
C150A (CASE 3)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | - |
| Command to main relay | On |
| Power supply for solenoid voltage | Higher than 6.0 V |
| Brake system voltage 1 | Less than 17.4 V |
C150A (CASE 4 AND 6)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| Both of the following conditions are met | - |
| Power supply for solenoid voltage | 6.0 V or more |
| Solenoid relay | On |
C150A (CASE 5)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | A, B, C, D and E |
| A. Command to main relay | On |
| B. Power supply for solenoid voltage | Higher than 6.0 V |
| C. Brake system voltage 1 | Less than 17.4 V |
| D. Following condition is met | 0.033 seconds or more |
| Brake pressure control solenoid target current value | 0 A |
| E. Solenoid load open/short to ground signal | Off |
C150A (CASE 7)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | A, B, C, D, E, F, G and H |
| A. Command to main relay | On |
| B. Power supply for solenoid voltage | 9.5 V or more |
| C. Brake system voltage 1 | Less than 17.4 V |
| D. Following condition is met | 0.033 seconds or more |
| Brake pressure control solenoid target current value | 0 A |
| E. Solenoid over current signal | Off |
| F. Solenoid driver overtemperature signal | Off |
| G. Solenoid return current terminal disconnection signal | Off |
| H. Solenoid GND terminal disconnection signal | Off |
C150A (CASE 8)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150F: Brake pressure control solenoid SGH circuit low C1510: Brake pressure control solenoid SGH circuit high |
| Solenoid current output order value | 150.00 mA |
C150F (CASE 1)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | A, B, C and D |
| A. Command to main relay | On |
| B. Power supply for solenoid voltage | Higher than 6.0 V |
| C. Brake system voltage 1 | Less than 17.4 V |
| D. Following condition is met | 0.033 seconds or more |
| Brake pressure control solenoid target current value | 0 A |
C150F (CASE 2 AND 4)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C1510: Brake pressure control solenoid SGH circuit high |
| Both of the following conditions are met | - |
| Power supply for solenoid voltage | 6.0 V or more |
| Solenoid relay | On |
C150F (CASE 3)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | - |
| Command to main relay | On |
| Power supply for solenoid voltage | Higher than 6.0 V |
| Brake system voltage 1 | Less than 17.4 V |
C150F (CASE 5)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C1510: Brake pressure control solenoid SGH circuit high |
| All of the following conditions are met | A, B, C, D, E, F, G and H |
| A. Command to main relay | On |
| B. Power supply for solenoid voltage | 9.5 V or more |
| C. Brake system voltage 1 | Less than 17.4 V |
| D. Following condition is met | 0.012 seconds or more |
| Brake pressure control solenoid target current value | 0.348 A |
| E. Solenoid over current signal | Off |
| F. Solenoid driver overtemperature signal | Off |
| G. Solenoid return current terminal disconnection signal | Off |
| H. Solenoid GND terminal disconnection signal | Off |
C150F (CASE 6)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C1510: Brake pressure control solenoid SGH circuit high |
| Solenoid current output order value | 150.00 mA |
C1510 (CASE 1)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low |
| All of the following conditions are met | A, B, C, D, E, F, G, H, I and J |
| A. Command to main relay | On |
| B. Power supply for solenoid voltage | Higher than 6.0 V |
| C. Brake system voltage 1 | Less than 17.4 V |
| D. Following condition is met | 0.033 seconds or more |
| Brake pressure control solenoid target current value | 0 A |
| E. Solenoid over current signal | Off |
| F. Solenoid driver overtemperature signal | Off |
| G. Solenoid load open/short to ground signal | Off |
| H. Solenoid load leakage signal | Off |
| I. Solenoid return current terminal disconnection signal | Off |
| J. Solenoid GND terminal disconnection signal | Off |
C1510 (CASE 2)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low |
| Both of the following conditions are met | - |
| Brake system voltage 1 | Higher than 7.3 V |
| Solenoid current output order value | 0.70 mA |
C1510 (CASE 3)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low |
| All of the following conditions are met | - |
| Command to main relay | On |
| Power supply for solenoid voltage | Higher than 6.0 V |
| Brake system voltage 1 | Less than 17.4 V |
C1510 (CASE 4 AND 6)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low |
| Both of the following conditions are met | - |
| Power supply for solenoid voltage | 6.0 V or more |
| Solenoid relay | On |
C1510 (CASE 5)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low |
| All of the following conditions are met | A, B, C, D and E |
| A. Command to main relay | On |
| B. Power supply for solenoid voltage | Higher than 6.0 V |
| C. Brake system voltage 1 | Less than 17.4 V |
| D. Following condition is met | 0.033 seconds or more |
| Brake pressure control solenoid target current value | 0 A |
| E. Solenoid load open/short to ground signal | Off |
C1510 (CASE 7)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low |
| All of the following conditions are met | A, B, C, D, E, F, G and H |
| A. Command to main relay | On |
| B. Power supply for solenoid voltage | 9.5 V or more |
| C. Brake system voltage 1 | Less than 17.4 V |
| D. Following condition is met | 0.033 seconds or more |
| Brake pressure control solenoid target current value | 0 A |
| E. Solenoid over current signal | Off |
| F. Solenoid driver overtemperature signal | Off |
| G. Solenoid return current terminal disconnection signal | Off |
| H. Solenoid GND terminal disconnection signal | Off |
C1510 (CASE 8)
| Monitor runs whenever the following DTCs are not stored | C12FA: Brake system voltage power supply relay open circuit C14C8: Brake system voltage circuit high C14F3: Brake pressure control solenoid SLA circuit low C14F4: Brake pressure control solenoid SLA circuit high C14FC: Brake pressure control solenoid SLR circuit low C14FD: Brake pressure control solenoid SLR circuit high C1509: Brake pressure control solenoid SSA circuit low C150A: Brake pressure control solenoid SSA circuit high C150F: Brake pressure control solenoid SGH circuit low |
| Solenoid current output order value | 150.00 mA |