DTC C121F-49: Lost Communication with Electronic Brake Booster Control Module "A" Internal Electronic Failure; DTC C14F1-12: Brake Pressure Control Solenoid "C" Control Circuit Short to Battery; DTC C14F1-14: Brake Pressure Control Solenoid "C" Control Circuit Short to Ground or Open; DTC C14F1-18: Brake Pressure Control Solenoid "C" Control Circuit Current Below Threshold; DTC C14F1-19: Brake Pressure Control Solenoid "C" Control Circuit Current Above Threshold; DTC C14F1-1D: Brake Pressure Control Solenoid "C" Control Circuit Current Out of Range; DTC C14FA-12: Brake Pressure Control Solenoid "D" Control Circuit Short to Battery; DTC C14FA-14: Brake Pressure Control Solenoid "D" Control Circuit Short to Ground or Open; DTC C14FA-18: Brake Pressure Control Solenoid "D" Control Circuit Current Below Threshold; DTC C14FA-19: Brake Pressure Control Solenoid "D" Control Circuit Current Above Threshold; DTC C14FA-1D: Brake Pressure Control Solenoid "D" Control Circuit Current Out of Range; DTC C1507-12: Brake Pressure Control solenoid "E" Control Circuit Short to Battery; DTC C1507-14: Brake Pressure Control solenoid "E" Control Circuit Short to Ground or Open; DTC C1507-18: Brake Pressure Control solenoid "E" Control Circuit Current Below Threshold; DTC C1507-19: Brake Pressure Control solenoid "E" Control Circuit Current Above Threshold; DTC C1507-1D: Brake Pressure Control solenoid "E" Control Circuit Current Out of Range; DTC C150D-12: Brake Pressure Control solenoid "F" Control Circuit Short to Battery; DTC C150D-14: Brake Pressure Control solenoid "F" Control Circuit Short to Ground or Open; DTC C150D-18: Brake Pressure Control solenoid "F" Control Circuit Current Below Threshold; DTC C150D-19: Brake Pressure Control solenoid "F" Control Circuit Current Above Threshold; DTC C150D-1D: Brake Pressure Control solenoid "F" Control Circuit Current Out of Range [10/2021 - ]: Description
WARNING: This page is about a different variant/trim than selected.
The linear solenoids SLA and SLR control the regulator based on signals from the No. 1 skid control ECU (brake booster with master cylinder assembly) and produce servo pressure in accordance with the vehicle condition.
When the system is normal, the switching solenoid SGH is opened to allow brake fluid to flow to the stroke simulator when the brake pedal is depressed. When the system is abnormal, the switching solenoid SGH closes to prevent the flow of brake fluid.
When the system is normal, the switching solenoid SSA is closed. When the system is abnormal, the switching solenoid SSA is opened to allow fluid to flow to the brake master cylinder reservoir assembly.
HINT:
- If the supply voltage decreases, a drop in current may cause DTCs to be stored.
- Brake pressure control solenoid "C": Solenoid SLA.
- Brake pressure control solenoid "D": Solenoid SLR.
- Brake pressure control solenoid "E": Solenoid SSA.
- Brake pressure control solenoid "F": Solenoid SGH.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Note |
|---|---|---|---|---|---|
| C121F-49 | Lost Communication with Electronic Brake Booster Control Module "A" Internal Electronic Failure | When the voltage at terminal +BI1 is between 7.3 V and 16.6 V, the voltage of the booster circuit inside the ECU is excessively low for 0.1 seconds or more. | Brake booster with master cylinder assembly | Comes on |
|
| C14F1-12 | Brake Pressure Control Solenoid "C" Control Circuit Short to Battery | An excessive current is detected in the solenoid for 0.05 seconds or more. |
|
Comes on |
|
| C14F1-14 | Brake Pressure Control Solenoid "C" Control Circuit Short to Ground or Open | Insufficient current is detected in the solenoid for 0.05 seconds or more. | Brake booster with master cylinder assembly | Comes on |
|
| C14F1-18 | Brake Pressure Control Solenoid "C" Control Circuit Current Below Threshold | An open is detected in the solenoid for 0.05 seconds or more. | Brake booster with master cylinder assembly | Comes on |
|
| C14F1-19 | Brake Pressure Control Solenoid "C" Control Circuit Current Above Threshold | Overcurrent is detected in the solenoid for 0.05 seconds or more. | Brake booster with master cylinder assembly | Comes on |
|
| C14F1-1D | Brake Pressure Control Solenoid "C" Control Circuit Current Out of Range | Current leakage is detected in the solenoid for 0.05 seconds or more. | Brake booster with master cylinder assembly | Comes on |
|
| C14FA-12 | Brake Pressure Control Solenoid "D" Control Circuit Short to Battery | An excessive current is detected in the solenoid for 0.05 seconds or more. |
|
Comes on |
|
| C14FA-14 | Brake Pressure Control Solenoid "D" Control Circuit Short to Ground or Open | Insufficient current is detected in the solenoid for 0.05 seconds or more. | Brake booster with master cylinder assembly | Comes on |
|
| C14FA-18 | Brake Pressure Control Solenoid "D" Control Circuit Current Below Threshold | An open is detected in the solenoid for 0.05 seconds or more. | Brake booster with master cylinder assembly | Comes on |
|
| C14FA-19 | Brake Pressure Control Solenoid "D" Control Circuit Current Above Threshold | Overcurrent is detected in the solenoid for 0.05 seconds or more. | Brake booster with master cylinder assembly | Comes on |
|
| C14FA-1D | Brake Pressure Control Solenoid "D" Control Circuit Current Out of Range | Current leakage is detected in the solenoid for 0.05 seconds or more. | Brake booster with master cylinder assembly | Comes on |
|
| C1507-12 | Brake Pressure Control solenoid "E" Control Circuit Short to Battery | Monitoring value of SSA continues to be excessively higher than request value. |
|
Comes on |
|
| C1507-14 | Brake Pressure Control solenoid "E" Control Circuit Short to Ground or Open | Monitoring value of SSA continues to be excessively lower than request value. | Brake booster with master cylinder assembly | Comes on |
|
| C1507-18 | Brake Pressure Control solenoid "E" Control Circuit Current Below Threshold | An open is detected in SSA for 0.05 seconds or more. | Brake booster with master cylinder assembly | Comes on |
|
| C1507-19 | Brake Pressure Control solenoid "E" Control Circuit Current Above Threshold | Overcurrent is detected in SSA for 0.05 seconds or more. | Brake booster with master cylinder assembly | Comes on |
|
| C1507-1D | Brake Pressure Control solenoid "E" Control Circuit Current Out of Range | Current leakage is detected in SSA for 0.05 seconds or more. | Brake booster with master cylinder assembly | Comes on |
|
| C150D-12 | Brake Pressure Control solenoid "F" Control Circuit Short to Battery | Monitoring value of SGH continues to be excessively higher than request value. |
|
Comes on |
|
| C150D-14 | Brake Pressure Control solenoid "F" Control Circuit Short to Ground or Open | Monitoring value of SGH continues to be excessively lower than request value. | Brake booster with master cylinder assembly | Comes on |
|
| C150D-18 | Brake Pressure Control solenoid "F" Control Circuit Current Below Threshold | An open is detected in SGH for 0.05 seconds or more. | Brake booster with master cylinder assembly | Comes on |
|
| C150D-19 | Brake Pressure Control solenoid "F" Control Circuit Current Above Threshold | Overcurrent is detected in SGH for 0.05 seconds or more. | Brake booster with master cylinder assembly | Comes on |
|
| C150D-1D | Brake Pressure Control solenoid "F" Control Circuit Current Out of Range | Current leakage is detected in SGH for 0.05 seconds or more. | Brake booster with master cylinder assembly | Comes on |
|