Typical Malfunction Thresholds
WARNING: This page is about a different variant/trim than selected.
C053D (CASE 2)
| Master cylinder pressure sensor | Less than -0.744 MPa (-7.6 kgf/cm2 , -107 psi) |
C0540 (CASE 1)
| Master cylinder pressure sensor communication | Invalid |
C0540 (CASE 2)
| Master cylinder pressure sensor level | Higher than 23.328 MPa (237.9 kgf/cm2 , 3383 psi) |
C0540 (CASE 3)
| Master cylinder pressure sensor temperature level | Higher than 150°C (302°F) |
C0540 (CASE 4)
| Brake booster pressure sensor data | Invalid |
C056B
| Difference current master cylinder pressure and last master cylinder pressure | Higher than 15 MPa (153.0 kgf/cm2 , 2175 psi) |
C122E
| Master cylinder pressure sensor power supply voltage | 6.5 V or less |
C122F
| One of the following conditions is met | - |
| Master cylinder pressure sensor power supply voltage | Higher than 7.5 V |
| Master cylinder pressure sensor temperature | Higher than 175°C (347°F) |
| Master cylinder pressure sensor current | Higher than 50 mA |