Component Operating Range
WARNING: This page is about a different variant/trim than selected.
C053D (CASE 2)
| Both of the following conditions are met | - |
| Pressure sensor fail (C0540, C122F, C056B) | Not detected |
| Master cylinder pressure sensor | -0.744 MPa (-7.6 kgf/cm2 , -107 psi) or more |
C0540 (CASE 1)
| Master cylinder pressure sensor communication | Valid |
C0540 (CASE 2 AND 3)
| All of the following conditions are met | - |
| Master cylinder pressure sensor communication | Valid |
| Master cylinder pressure sensor level | 23.328 MPa (237.9 kgf/cm2 , 3383 psi) or less |
| Master cylinder pressure sensor temperature level | 150°C (302°F) or less |
C0540 (CASE 4)
| All of the following conditions are met | - |
| +BS voltage | Less than 8.5 V |
| Master cylinder pressure sensor temperature | Less than 175°C (347°F) |
| Master cylinder pressure sensor current | Less than 0.05 A |
| Master cylinder pressure sensor power supply voltage | Higher than 6.5 V, and less than 7.5 V |
| Brake booster pressure sensor data | Valid |
C056B
| All of the following conditions are met | - |
| Master cylinder pressure sensor power supply effective invalidity | Valid |
| Master cylinder pressure sensor power supply voltage | Higher than 6.5 V, and less than 7.5 V |
| Master cylinder pressure sensor communication | Valid |
| Difference current master cylinder pressure and last master cylinder pressure | 15 MPa (153.0 kgf/cm2 , 2175 psi) or less |
C122E AND C122F
| Both of the following conditions are met | - |
| Master cylinder pressure sensor power supply effective invalidity | Valid |
| Master cylinder pressure sensor power supply voltage | Higher than 6.5 V, and less than 7.5 V |