WARNING: This page is about a different variant/trim than selected.
| Related DTCs | C0573 (Case 2): Accumulator pressure sensor internal malfunction C0573 (Case 3): Accumulator pressure sensor invalid data C0573 (Case 4): Accumulator pressure sensor lost communication C0577 (Case 1): Reaction force pressure sensor lost communication C0577 (Case 2): Reaction force pressure sensor internal malfunction C0577 (Case 3): Reaction force pressure sensor invalid data C05A1 (Case 1): Servo pressure sensor lost communication C05A1 (Case 2): Servo pressure sensor internal malfunction C05A1 (Case 3): Servo pressure sensor invalid data C1496: Reaction force pressure sensor voltage circuit low C1497: Reaction force pressure sensor voltage circuit high C1498: Servo pressure sensor voltage circuit low C1499: Servo pressure sensor voltage circuit high C149E: Accumulator pressure sensor voltage circuit low C149F: Accumulator pressure sensor voltage circuit high C14B4: Reaction force pressure sensor intermittent/erratic C14C4: Servo pressure sensor intermittent/erratic C14D3: Accumulator pressure sensor intermittent/erratic |
| Required Sensors/Components (Main) | No. 2 skid control ECU (brake actuator assembly) Brake actuator (brake booster with master cylinder assembly) Brake actuator assembly |
| Required Sensors/Components (Related) | No. 2 skid control ECU (brake actuator assembly) Brake actuator (brake booster with master cylinder assembly) Brake actuator assembly |
| Frequency of Operation | Continuous |
| Duration | 0.054 seconds: C0573 (Case 2), C0577 (Case 1 and 2), C05A1 (Case 1 and 2), C1496, C1497, C1498, C1499, C149E and C149F 0.096 seconds: C14B4, C14C4 and C14D3 0.198 seconds: C0573 (Case 4), C0577 (Case 3) and C05A1 (Case 3) 0.798 seconds: C0573 (Case 3) |
| MIL Operation | Immediately |
| Sequence of Operation | None |