Typical Enabling Conditions
WARNING: This page is about a different variant/trim than selected.
C0573 (CASE 2)
| Monitor runs whenever the following DTCs are not stored | C149E: Accumulator pressure sensor voltage circuit low C149F: Accumulator pressure sensor voltage circuit high |
| All of the following conditions are met | - |
| Communication with pressure sensor | Valid |
| Pressure sensor start state | Valid |
| Master cylinder pressure sensor power supply voltage | Higher than 6.5 V and less than 7.5 V |
| Master cylinder pressure sensor temperature | 175°C (347°F) or less |
| Master cylinder pressure sensor current | Less than 50.00 mA |
C0573 (CASE 3), C0577 (CASE 3) AND C05A1 (CASE 3)
| Monitor runs whenever the following DTCs are not stored | None |
| All of the following conditions are met | - |
| Brake system voltage 1 | Higher than 8.50 V |
| Communication with pressure sensor | Valid |
| Master cylinder pressure sensor power supply voltage | Higher than 6.5 V and less than 7.5 V |
| Pressure sensor fail (C1497, C149F, C1499) | Not detected |
| Pressure sensor fail (C1496, C149E, C1498) | Not detected |
| Pressure sensor fail (C0577, C0573, C05A1) | Not detected |
| Pressure sensor fail (C14B4, C14D3, C14C4) | Not detected |
C0573 (CASE 4)
| Monitor runs whenever the following DTCs are not stored | C149E: Accumulator pressure sensor voltage circuit low C149F: Accumulator pressure sensor voltage circuit high |
| All of the following conditions are met | - |
| Pressure sensor start state | Valid |
| Master cylinder pressure sensor power supply voltage | Higher than 6.5 V and less than 7.5 V |
| Master cylinder pressure sensor temperature | 175°C (347°F) or less |
| Master cylinder pressure sensor current | Less than 50.00 mA |
C0577 (CASE 1)
| Monitor runs whenever the following DTCs are not stored | C1496: Reaction force pressure sensor voltage circuit low C1497: Reaction force pressure sensor voltage circuit high |
| All of the following conditions are met | - |
| Pressure sensor start state | Valid |
| Master cylinder pressure sensor power supply voltage | Higher than 6.5 V and less than 7.5 V |
| Master cylinder pressure sensor temperature | 175°C (347°F) or less |
| Master cylinder pressure sensor current | Less than 50.00 mA |
C0577 (CASE 2)
| Monitor runs whenever the following DTCs are not stored | C1496: Reaction force pressure sensor voltage circuit low C1497: Reaction force pressure sensor voltage circuit high |
| All of the following conditions are met | - |
| Communication with pressure sensor | Valid |
| Pressure sensor start state | Valid |
| Master cylinder pressure sensor power supply voltage | Higher than 6.5 V and less than 7.5 V |
| Master cylinder pressure sensor temperature | 175°C (347°F) or less |
| Master cylinder pressure sensor current | Less than 50.00 mA |
C05A1 (CASE 1)
| Monitor runs whenever the following DTCs are not stored | C1498: Servo pressure sensor voltage circuit low C1499: Servo pressure sensor voltage circuit high |
| All of the following conditions are met | - |
| Pressure sensor start state | Valid |
| Master cylinder pressure sensor power supply voltage | Higher than 6.5 V and less than 7.5 V |
| Master cylinder pressure sensor temperature | 175°C (347°F) or less |
| Master cylinder pressure sensor current | Less than 50.00 mA |
C05A1 (CASE 2)
| Monitor runs whenever the following DTCs are not stored | C1498: Servo pressure sensor voltage circuit low C1499: Servo pressure sensor voltage circuit high |
| All of the following conditions are met | - |
| Communication with pressure sensor | Valid |
| Pressure sensor start state | Valid |
| Master cylinder pressure sensor power supply voltage | Higher than 6.5 V and less than 7.5 V |
| Master cylinder pressure sensor temperature | 175°C (347°F) or less |
| Master cylinder pressure sensor current | Less than 50.00 mA |
C1496, C1498 AND C149E
| Monitor runs whenever the following DTCs are not stored | C1499: Servo pressure sensor voltage circuit high C14C7 (Case 3 to 9): Brake system voltage circuit low |
| All of the following conditions are met | - |
| Pressure sensor start state | Valid |
| Brake system voltage 1 | Higher than 8.5 V |
C14B4, C14C4 AND C14D3
| Monitor runs whenever the following DTCs are not stored | C05A1 (Case 1): Servo pressure sensor lost communication C05A1 (Case 2): Servo pressure sensor internal malfunction C05A1 (Case 3): Servo pressure sensor invalid data C1496: Reaction force pressure sensor voltage circuit low C1497: Reaction force pressure sensor voltage circuit high |
| All of the following conditions are met | - |
| Communication with pressure sensor | Valid |
| Pressure sensor start state | Valid |
| Master cylinder pressure sensor power supply voltage | Higher than 6.5 V and less than 7.5 V |
| Master cylinder pressure sensor temperature | 175°C (347°F) or less |
| Master cylinder pressure sensor current | Less than 50.00 mA |