Typical Enabling Conditions
WARNING: This page is about a different variant/trim than selected.
C0597 (CASE 1)
| Monitor runs whenever the following DTCs are not stored | C12A7: ABS hold solenoid (FL) circuit low C12A8: ABS hold solenoid (FL) circuit high C12B2: ABS release solenoid (FL) circuit low C12B3: ABS release solenoid (FL) circuit high C12BD: ABS hold solenoid (FR) circuit low C12BE: ABS hold solenoid (FR) circuit high C12C8: ABS release solenoid (FR) circuit low C12C9: ABS release solenoid (FR) circuit high C12D3: ABS hold solenoid (RL) circuit low C12D4: ABS hold solenoid (RL) circuit high C12DE: ABS release solenoid (RL) circuit low C12DF: ABS release solenoid (RL) circuit high C12E9: ABS hold solenoid (RR) circuit low C12EA: ABS hold solenoid (RR) circuit high C12F4: ABS release solenoid (RR) circuit low C12F5: ABS release solenoid (RR) circuit high C12F6: ABS hold solenoid other functional C12F7: ABS hold solenoid other functional C137C: Brake system voltage input out of range low C137D: Brake system voltage input out of range high C13BF: SM solenoid other functional C13C2: SM1 solenoid circuit low C13C3: SM1 solenoid circuit high C13CB: SM2 solenoid circuit low C13CC: SM2 solenoid circuit high C143B: Brake system voltage solenoid relay stuck C143C: Brake system voltage open circuit |
| All of the following conditions are met | - |
| Command to solenoid relay | On |
| Power supply for solenoid | Higher than 6 V |
| +BS voltage | Higher than 9.5 V, and less than 17.4 V |
C0597 (CASE 2)
| Monitor runs whenever the following DTCs are not stored | C12A7: ABS hold solenoid (FL) circuit low C12A8: ABS hold solenoid (FL) circuit high C12B2: ABS release solenoid (FL) circuit low C12B3: ABS release solenoid (FL) circuit high C12BD: ABS hold solenoid (FR) circuit low C12BE: ABS hold solenoid (FR) circuit high C12C8: ABS release solenoid (FR) circuit low C12C9: ABS release solenoid (FR) circuit high C12D3: ABS hold solenoid (RL) circuit low C12D4: ABS hold solenoid (RL) circuit high C12DE: ABS release solenoid (RL) circuit low C12DF: ABS release solenoid (RL) circuit high C12E9: ABS hold solenoid (RR) circuit low C12EA: ABS hold solenoid (RR) circuit high C12F4: ABS release solenoid (RR) circuit low C12F5: ABS release solenoid (RR) circuit high C12F6: ABS hold solenoid other functional C12F7: ABS hold solenoid other functional C137C: Brake system voltage input out of range low C137D: Brake system voltage input out of range high C13BF: SM solenoid other functional C13C2: SM1 solenoid circuit low C13C3: SM1 solenoid circuit high C13CB: SM2 solenoid circuit low C13CC: SM2 solenoid circuit high C143B: Brake system voltage solenoid relay stuck C143C: Brake system voltage open circuit |
| All of the following conditions are met | - |
| +BS voltage | 9.5 V or more |
| Solenoid relay | Off |
| ASIC output permission | Off |
C0597 (CASE 3)
| Monitor runs whenever the following DTCs are not stored | C12A7: ABS hold solenoid (FL) circuit low C12A8: ABS hold solenoid (FL) circuit high C12B2: ABS release solenoid (FL) circuit low C12B3: ABS release solenoid (FL) circuit high C12BD: ABS hold solenoid (FR) circuit low C12BE: ABS hold solenoid (FR) circuit high C12C8: ABS release solenoid (FR) circuit low C12C9: ABS release solenoid (FR) circuit high C12D3: ABS hold solenoid (RL) circuit low C12D4: ABS hold solenoid (RL) circuit high C12DE: ABS release solenoid (RL) circuit low C12DF: ABS release solenoid (RL) circuit high C12E9: ABS hold solenoid (RR) circuit low C12EA: ABS hold solenoid (RR) circuit high C12F4: ABS release solenoid (RR) circuit low C12F5: ABS release solenoid (RR) circuit high C12F6: ABS hold solenoid other functional C12F7: ABS hold solenoid other functional C137C: Brake system voltage input out of range low C137D: Brake system voltage input out of range high C13BF: SM solenoid other functional C13C2: SM1 solenoid circuit low C13C3: SM1 solenoid circuit high C13CB: SM2 solenoid circuit low C13CC: SM2 solenoid circuit high C143B: Brake system voltage solenoid relay stuck C143C: Brake system voltage open circuit |
| All of the following conditions are met | - |
| +BS voltage | 9.5 V or more |
| Solenoid relay | On |
| ASIC output permission | Off |
| Solenoid current output order value | 160 mA |
| Power supply voltage for solenoid | 6 V or more |
C0597 (CASE 4)
| Monitor runs whenever the following DTCs are not stored | C12A7: ABS hold solenoid (FL) circuit low C12A8: ABS hold solenoid (FL) circuit high C12B2: ABS release solenoid (FL) circuit low C12B3: ABS release solenoid (FL) circuit high C12BD: ABS hold solenoid (FR) circuit low C12BE: ABS hold solenoid (FR) circuit high C12C8: ABS release solenoid (FR) circuit low C12C9: ABS release solenoid (FR) circuit high C12D3: ABS hold solenoid (RL) circuit low C12D4: ABS hold solenoid (RL) circuit high C12DE: ABS release solenoid (RL) circuit low C12DF: ABS release solenoid (RL) circuit high C12E9: ABS hold solenoid (RR) circuit low C12EA: ABS hold solenoid (RR) circuit high C12F4: ABS release solenoid (RR) circuit low C12F5: ABS release solenoid (RR) circuit high C12F6: ABS hold solenoid other functional C12F7: ABS hold solenoid other functional C137C: Brake system voltage input out of range low C137D: Brake system voltage input out of range high C13BF: SM solenoid other functional C13C2: SM1 solenoid circuit low C13C3: SM1 solenoid circuit high C13CB: SM2 solenoid circuit low C13CC: SM2 solenoid circuit high C143B: Brake system voltage solenoid relay stuck C143C: Brake system voltage open circuit |
| All of the following conditions are met | - |
| +BS voltage | 9.5 V or more |
| Solenoid relay | On |
| ASIC output permission | Off |
| NO solenoid current output order value | 160 mA |
| NC solenoid output order value | On |
| Power supply voltage for solenoid | 6 V or more |
C0597 (CASE 5)
| Monitor runs whenever the following DTCs are not stored | C12A7: ABS hold solenoid (FL) circuit low C12A8: ABS hold solenoid (FL) circuit high C12B2: ABS release solenoid (FL) circuit low C12B3: ABS release solenoid (FL) circuit high C12BD: ABS hold solenoid (FR) circuit low C12BE: ABS hold solenoid (FR) circuit high C12C8: ABS release solenoid (FR) circuit low C12C9: ABS release solenoid (FR) circuit high C12D3: ABS hold solenoid (RL) circuit low C12D4: ABS hold solenoid (RL) circuit high C12DE: ABS release solenoid (RL) circuit low C12DF: ABS release solenoid (RL) circuit high C12E9: ABS hold solenoid (RR) circuit low C12EA: ABS hold solenoid (RR) circuit high C12F4: ABS release solenoid (RR) circuit low C12F5: ABS release solenoid (RR) circuit high C12F6: ABS hold solenoid other functional C12F7: ABS hold solenoid other functional C137C: Brake system voltage input out of range low C137D: Brake system voltage input out of range high C13BF: SM solenoid other functional C13C2: SM1 solenoid circuit low C13C3: SM1 solenoid circuit high C13CB: SM2 solenoid circuit low C13CC: SM2 solenoid circuit high C143B: Brake system voltage solenoid relay stuck C143C: Brake system voltage open circuit |
| All of the following conditions are met | - |
| Solenoid relay | Off |
| ASIC output permission | Off |
| ASIC send data | NG answer |
C12F6
| Monitor runs whenever the following DTCs are not stored | C0597 (Case 1): ABS hold solenoid circuit stuck C0597 (Case 2 to 5): ABS hold solenoid performance C12A7: ABS hold solenoid (FL) circuit low C12A8: ABS hold solenoid (FL) circuit high C12B2: ABS release solenoid (FL) circuit low C12B3: ABS release solenoid (FL) circuit high C12BD: ABS hold solenoid (FR) circuit low C12BE: ABS hold solenoid (FR) circuit high C12C8: ABS release solenoid (FR) circuit low C12C9: ABS release solenoid (FR) circuit high C12D3: ABS hold solenoid (RL) circuit low C12D4: ABS hold solenoid (RL) circuit high C12DE: ABS release solenoid (RL) circuit low C12DF: ABS release solenoid (RL) circuit high C12E9: ABS hold solenoid (RR) circuit low C12EA: ABS hold solenoid (RR) circuit high C12F4: ABS release solenoid (RR) circuit low C12F5: ABS release solenoid (RR) circuit high C12F7: ABS hold solenoid other functional C137C: Brake system voltage input out of range low C137D: Brake system voltage input out of range high C13BF: SM solenoid other functional C13C2: SM1 solenoid circuit low C13C3: SM1 solenoid circuit high C13CB: SM2 solenoid circuit low C13CC: SM2 solenoid circuit high C143B: Brake system voltage solenoid relay stuck C143C: Brake system voltage open circuit |
| All of the following conditions are met | A, B, C, D, E, F, G and H |
| A. Command to solenoid relay | On |
| B. Power supply for solenoid | 9.5 V or more |
| C. +BS voltage | Less than 17.4 V |
| D. Following condition is met | 0.120 seconds or more |
| Difference SFRH target current value (0.018 seconds before) and SFRH target current value | Less than 0.022 A |
| E. Following condition is met | 0.120 seconds or more |
| Difference SFLH target current value (0.018 seconds before) and SFLH target current value | Less than 0.022 A |
| F. SFRH target current value | SFLH target current value |
| G. SFRH target current value | 0.25 A or more, and 1 A or less |
| H. SFLH target current value | 0.25 A or more, and 1 A or less |
C12F7
| Monitor runs whenever the following DTCs are not stored | C0597 (Case 1): ABS hold solenoid circuit stuck C0597 (Case 2 to 5): ABS hold solenoid performance C12A7: ABS hold solenoid (FL) circuit low C12A8: ABS hold solenoid (FL) circuit high C12B2: ABS release solenoid (FL) circuit low C12B3: ABS release solenoid (FL) circuit high C12BD: ABS hold solenoid (FR) circuit low C12BE: ABS hold solenoid (FR) circuit high C12C8: ABS release solenoid (FR) circuit low C12C9: ABS release solenoid (FR) circuit high C12D3: ABS hold solenoid (RL) circuit low C12D4: ABS hold solenoid (RL) circuit high C12DE: ABS release solenoid (RL) circuit low C12DF: ABS release solenoid (RL) circuit high C12E9: ABS hold solenoid (RR) circuit low C12EA: ABS hold solenoid (RR) circuit high C12F4: ABS release solenoid (RR) circuit low C12F5: ABS release solenoid (RR) circuit high C12F6: ABS hold solenoid other functional C137C: Brake system voltage input out of range low C137D: Brake system voltage input out of range high C13BF: SM solenoid other functional C13C2: SM1 solenoid circuit low C13C3: SM1 solenoid circuit high C13CB: SM2 solenoid circuit low C13CC: SM2 solenoid circuit high C143B: Brake system voltage solenoid relay stuck C143C: Brake system voltage open circuit |
| All of the following conditions are met | A, B, C, D, E, F, G and H |
| A. Command to solenoid relay | On |
| B. Power supply for solenoid | 9.5 V or more |
| C. +BS voltage | Less than 17.4 V |
| D. Following condition is met | 0.120 seconds or more |
| Difference SRRH target current value (0.018 seconds before) and SRRH target current value | Less than 0.022 A |
| E. Following condition is met | 0.120 seconds or more |
| Difference SRLH target current value (0.018 seconds before) and SRLH target current value | Less than 0.022 A |
| F. SRRH target current value | SRLH target current value |
| G. SRRH target current value | 0.25 A or more, and 1 A or less |
| H. SRLH target current value | 0.25 A or more, and 1 A or less |
C13BF
| Monitor runs whenever the following DTCs are not stored | C0597 (Case 1): ABS hold solenoid circuit stuck C0597 (Case 2 to 5): ABS hold solenoid performance C12A7: ABS hold solenoid (FL) circuit low C12A8: ABS hold solenoid (FL) circuit high C12B2: ABS release solenoid (FL) circuit low C12B3: ABS release solenoid (FL) circuit high C12BD: ABS hold solenoid (FR) circuit low C12BE: ABS hold solenoid (FR) circuit high C12C8: ABS release solenoid (FR) circuit low C12C9: ABS release solenoid (FR) circuit high C12D3: ABS hold solenoid (RL) circuit low C12D4: ABS hold solenoid (RL) circuit high C12DE: ABS release solenoid (RL) circuit low C12DF: ABS release solenoid (RL) circuit high C12E9: ABS hold solenoid (RR) circuit low C12EA: ABS hold solenoid (RR) circuit high C12F4: ABS release solenoid (RR) circuit low C12F5: ABS release solenoid (RR) circuit high C12F6: ABS hold solenoid other functional C12F7: ABS hold solenoid other functional C137C: Brake system voltage input out of range low C137D: Brake system voltage input out of range high C13C2: SM1 solenoid circuit low C13C3: SM1 solenoid circuit high C13CB: SM2 solenoid circuit low C13CC: SM2 solenoid circuit high C143B: Brake system voltage solenoid relay stuck C143C: Brake system voltage open circuit |
| All of the following conditions are met | A, B, C, D, E, F, G and H |
| A. Command to solenoid relay | On |
| B. Power supply for solenoid | 9.5 V or more |
| C. +BS voltage | Less than 17.4 V |
| D. Following condition is met | 0.240 seconds or more |
| Difference SM1 target current value (0.018 seconds before) and SM1 target current value | Less than 0.022 A |
| E. Following condition is met | 0.240 seconds or more |
| Difference SM2 target current value (0.018 seconds before) and SM2 target current value | Less than 0.022 A |
| F. SM1 target current value | SM2 target current value |
| G. SM1 target current value | 0.348 A or more, and 0.568 A or less |
| H. SM2 target current value | 0.348 A or more, and 0.568 A or less |