Typical Enabling Conditions
WARNING: This page is about a different variant/trim than selected.
C050D (CASE 4)
| Monitor runs whenever the following DTCs are not stored | C050D (Case 1 to 3): Wheel speed sensor (RL) range/performance C050E: Wheel speed sensor (RL) voltage circuit open C050F: Wheel speed sensor (RL) voltage circuit high C0510: Wheel speed sensor (RL) intermittent/erratic C1021 (Case 1): Brake system voltage input out of range low C137D: Brake system voltage input out of range high C14E7: Wheel speed sensor (RL) voltage circuit low |
| All of the following conditions are met | - |
| Chassis dynamometer mode | Off |
| +BS voltage | 17.4 V or less |
| IGR voltage | 3.5 V or more |
C0513 (CASE 4)
| Monitor runs whenever the following DTCs are not stored | C0513 (Case 1 to 3): Wheel speed sensor (RR) range/performance C0514: Wheel speed sensor (RR) voltage circuit open C0515: Wheel speed sensor (RR) voltage circuit high C0516: Wheel speed sensor (RR) intermittent/erratic C1021 (Case 1): Brake system voltage input out of range low C137D: Brake system voltage input out of range high C14EA: Wheel speed sensor (RR) voltage circuit low |
| All of the following conditions are met | - |
| Chassis dynamometer mode | Off |
| +BS voltage | 17.4 V or less |
| IGR voltage | 3.5 V or more |