Typical Enabling Conditions
WARNING: This page is about a different variant/trim than selected.
C0501 (CASE 4)
| Monitor runs whenever the following DTCs are not stored | C0501 (Case 1 to 3): Wheel speed sensor (FL) range/performance C0502: Wheel speed sensor (FL) voltage circuit open C0503: Wheel speed sensor (FL) voltage circuit high C0504: Wheel speed sensor (FL) intermittent/erratic C1021 (Case 1): Brake system voltage input out of range low C137D: Brake system voltage input out of range high C14E1: Wheel speed sensor (FL) voltage circuit low |
| All of the following conditions are met | - |
| Chassis dynamometer mode | Off |
| +BS voltage | 17.4 V or less |
| IGR voltage | 3.5 V or more |
C0507 (CASE 4)
| Monitor runs whenever the following DTCs are not stored | C0507 (Case 1 to 3): Wheel speed sensor (FR) range/performance C0508: Wheel speed sensor (FR) voltage circuit open C0509: Wheel speed sensor (FR) voltage circuit high C050A: Wheel speed sensor (FR) intermittent/erratic C1021 (Case 1): Brake system voltage input out of range low C137D: Brake system voltage input out of range high C14E4: Wheel speed sensor (FR) voltage circuit low |
| All of the following conditions are met | - |
| Chassis dynamometer mode | Off |
| +BS voltage | 17.4 V or less |
| IGR voltage | 3.5 V or more |