Inspection [12/2019 - ]: Procedure
- INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY
- Resistance Check
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Hazard Warning Signal Switch Assembly)Standard Resistance
Tester Connection Condition Specified Condition 6 (TB) - 3 (E) Hazard warning switch off 10 kΩ or higher Hazard warning switch on Below 50 Ω If the result is not as specified, replace the hazard warning signal switch assembly.
- Measure the resistance according to the value(s) in the table below.
- Illumination Inspection
- Apply auxiliary battery voltage to the hazard warning signal switch assembly and check that the switch illuminates.
OK
Measurement Condition Condition Specified Condition Auxiliary battery positive (+) → Terminal 7 (ILL+)
Auxiliary battery negative (-) → Terminal 2 (ILL-)Always Switch illumination illuminates If the result is not as specified, replace the hazard warning signal switch assembly.
- Apply auxiliary battery voltage to the hazard warning signal switch assembly and check that the switch illuminates.
- Resistance Check