Inspection [12/2019 - ]: Procedure
- INSPECT AUTO HIGH BEAM SWITCH
- Inspect the automatic high beam main switch.
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Auto High Beam Switch)Standard Resistance
Tester Connection Switch Condition Specified Condition 5 (B) - 2 (E) Automatic high beam main switch off 10 kΩ or higher Automatic high beam main switch on Below 1 Ω If the result is not as specified, replace the auto high beam switch.
- Measure the resistance according to the value(s) in the table below.
- Illumination Inspection
- Apply auxiliary battery voltage to the auto high beam switch and check that the switch illuminates.
OK
SWITCH ILLUMINATIONAuxiliary Battery Connection Specified Condition Auxiliary battery positive (+) → 6 (ILL+)
Auxiliary battery negative (-) → 1 (ILL-)Switch illumination illuminates OK
SWITCH INDICATORAuxiliary Battery Connection Specified Condition Auxiliary battery positive (+) → 3 (IND+)
Auxiliary battery negative (-) → 4 (AZBI)Switch indicator illuminates If the result is not as specified, replace the auto high beam switch.
- Apply auxiliary battery voltage to the auto high beam switch and check that the switch illuminates.
- Inspect the automatic high beam main switch.