DTC Summary
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | Note |
|---|---|---|---|---|---|---|
| P0441-7E | Evaporative Emission System Incorrect Purge Flow Actuator Stuck On | Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. Reference pressure is measured at start and at end of leak check. If stabilized pressure higher than [second reference pressure x 0.2], ECM determines that purge VSV stuck open. |
|
Comes on | DTC stored | SAE Code: P0441 DTC for Mexico Models: - Does not apply |
| P0441-7F | Evaporative Emission System Incorrect Purge Flow Actuator Stuck Off | After EVAP leak check performed, purge VSV turned on (open), and atmospheric air introduced into EVAP system. Reference pressure is measured at start and at end of check. If pressure does not return to near atmospheric pressure, ECM determines that purge VSV stuck closed. |
|
Comes on | DTC stored | SAE Code: P0441 DTC for Mexico Models: - Does not apply |
| P0441-9C | Evaporative Emission System Incorrect Purge Flow Low/Insufficient Flow | While engine running, following conditions successively met:
|
|
Comes on | DTC stored | SAE Code: P0441 DTC for Mexico Models: - Does not apply |
| DTC No. | Monitoring Item | Detection Timing | Detection Logic | SAE |
|---|---|---|---|---|
| P0441-7E | Purge VSV (Vacuum Switching Valve) stuck open | EVAP monitoring (ignition switch off) |
2 trip | P0441 |
| P0441-7F | Purge VSV stuck closed | EVAP monitoring (ignition switch off) |
2 trip | P0441 |
| P0441-9C | Purge flow | Engine running | 2 trip | P0441 |