Typical Malfunction Thresholds
PURGE VSV STUCK OPEN
| EVAP pressure when vacuum introduction is complete | Higher than [reference pressure x 0.2] |
PURGE VSV STUCK CLOSED
| EVAP pressure change for 10 seconds after purge VSV ON (open) | Less than 0.3 kPa (gauge) [0.044 psi (gauge)] |
PURGE FLOW
| Both of the following conditions are met: | 1 and 2 |
| 1. EVAP pressure change when purge flow is started | Less than 0.1 kPa (gauge) [0.015 psi (gauge)] |