Typical Enabling Conditions
P0365: EXHAUST VVT SENSOR (BANK 1) VERIFY PULSE INPUT (CASE 1)
| Monitor runs whenever the following DTCs are not stored | None |
| Both of the following conditions are met | - |
| Starter | After off to on timing |
| Minimum battery voltage while starter on | Less than 11 V |
P0365: EXHAUST VVT SENSOR (BANK 1) VERIFY PULSE INPUT (CASE 2)
| All of the following conditions are met | - |
| Engine speed | 600 rpm or higher |
| Exhaust VVT sensor range check fail (P0367, P0368) | Not detected |
| Ignition Switch | ON |
| Starter | Off |
| Battery voltage | 8 V or higher |
| Exhaust VVT sensor voltage | 0.3 to 4.7 V |
| Idling stop control (w/ stop and start system) | Not operating |
P0390: EXHAUST VVT SENSOR (BANK 2) VERIFY PULSE INPUT
| All of the following conditions are met | - |
| Engine speed | 600 rpm or higher |
| Exhaust VVT sensor range check fail (P0392, P0393) | Not detected |
| Ignition Switch | ON |
| Starter | Off |
| Battery voltage | 8 V or higher |
| Exhaust VVT sensor voltage | 0.3 to 4.7 V |
| Idling stop control (w/ stop and start system) | Not operating |