DSD Information System
Home >> Toyota >> 2021 >> Highlander LE, 4WD >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System (2GR-FKS) - Diagnostic Codes (1 Of 6) >> SFI System >> DTC P0010-13: A Camshaft Position Actuator Bank 1 Circuit Open; DTC P0020-13: Camshaft Position "A" Actuator Bank 2 Circuit Open [12/2019 - 10/2022] >> Typical Enabling Conditions

Typical Enabling Conditions

ALL

Monitor runs whenever the following DTCs are not stored None
All of the following conditions are met -
Battery voltage 8 V or higher
Starter Off
Ignition switch ON
Time after ignition switch off to ON 0.5 seconds or more
CASE 1

Either of the following conditions is met A or B
A. Both of the following conditions are met -
Battery voltage 11 V or higher, and less than 13 V
Target duty cycle Less than 75%
B. Both of the following conditions are met -
Battery voltage 13 V or higher
Target duty cycle Less than 90%
CASE 2

Both of the following conditions are met -
Current cut status Not cut
Target duty cycle 25% or higher