Monitor Strategy
| Related DTCs | P0037: Heated oxygen sensor (bank 1 sensor 2) heater range check (low current) P0038: Heated oxygen sensor (bank 1 sensor 2) heater range check (high current) P0057: Heated oxygen sensor (bank 2 sensor 2) heater range check (low current) P0058: Heated oxygen sensor (bank 2 sensor 2) heater range check (high current) P0141: Heated oxygen sensor (bank 1 sensor 2) heater performance P0161: Heated oxygen sensor (bank 2 sensor 2) heater performance P102D: Heated oxygen sensor (bank 1 sensor 2) heater performance P105D: Heated oxygen sensor (bank 2 sensor 2) heater performance |
| Required Sensors/Components (Main) | Heated oxygen sensor (sensor 2) heater |
| Required Sensors/Components (Related) | - |
| Frequency of Operation | Continuous: P0037, P0038, P0056, P0058, P102D, P105D Once per driving cycle: P0141, P0161 |
| Duration | 0.5 seconds: P0037, P0057, P102D, P105D 2.064 seconds: P0038, P0058 10 seconds: P0141, P0161 |
| MIL Operation | Immediate: P0037, P0038, P0056, P0058, P102D, P105D 2 driving cycles: P0141, P0161 |
| Sequence of Operation | None |