Inspection [12/2019 - 10/2022]: Procedure
- INSPECT FUEL PRESSURE SENSOR (FUEL DELIVERY PIPE WITH SENSOR ASSEMBLY) NOTE:
- Do not remove the fuel pressure sensor from the fuel delivery pipe with sensor assembly.
- If the fuel pressure sensor is removed, replace the fuel pressure sensor (fuel delivery pipe with sensor assembly) with a new one.
- Check the fuel pressure sensor (fuel delivery pipe with sensor assembly) output voltage.
- Apply 5 V between terminals 1 (VC) and 3 (E2).
*a Component without harness connected
(Fuel Pressure Sensor (Fuel Delivery Pipe with Sensor Assembly))*b Voltage Applied between Terminals NOTE:- Be careful when connecting the leads, as the fuel pressure sensor (fuel delivery pipe with sensor assembly) may be damaged if the leads are connected to the wrong terminals.
- Do not apply more than 6 V to terminals 1 (VC) or 3 (E2).
HINT:
If a stable power supply is not available, connect 4 nickel-metal hydride batteries (1.2 V each) or equivalent in series.
- Measure the voltage according to the value(s) in the table below.
*a Component without harness connected
(Fuel Pressure Sensor (Fuel Delivery Pipe with Sensor Assembly))Standard Voltage
Tester Connection Condition Specified Condition 2 (PFL) - 3 (E2) Pressure not applied to fuel pressure sensor (fuel delivery pipe with sensor assembly) Approximately 0.57 to 0.95 V* *: The output voltage changes depending on the voltage applied to the terminals.
If the result is not as specified, replace the fuel pressure sensor (fuel delivery pipe with sensor assembly).
- Apply 5 V between terminals 1 (VC) and 3 (E2).