Fail-Safe Chart [10/2022 - 11/2023]
If any of the following DTCs are stored, the engine stop and start ECU enters fail-safe mode to preserve vehicle operability.
| DTC | Component | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|---|
| P0555-00 P0555-2A |
|
|
One of the following conditions is met:
|
| P0555-11 P0555-15 |
Vacuum sensor assembly circuit |
|
Sensor output is within standard range |
| P0606-29 | Engine stop and start ECU |
|
Pass condition detected and ignition switch turned to ON |
| P060B-1C P060B-49 P060B-71 |
Analog to digital converter (Engine stop and start ECU) | Stop and start control is prohibited | Pass condition detected and ignition switch turned to ON |
| P1589-54 | G sensor zero point calibration incomplete |
|
Pass condition detected and ignition switch turned to ON |
| P0615-11 | ST relay circuit | Stop and start control is prohibited | Pass condition detected and DTCs are cleared |
| P0615-19 | Starter circuit |
|
Communication with ECM returns to normal and one of the following conditions is met:
|
| P1644-00 |
|
|
Voltage of engine stop and start ECU internal drive circuit for starter is correct when engine is idling and restarted |
| P2530-14 | IG signal circuit |
|
All of the following conditions are met for 10 seconds or more:
|
| P323A-00 P323A-16 P323B-14 P323B-29 P323B-38 |
Backup boost converter circuit |
|
Pass condition detected and DTCs are cleared |
| U0100-87 | CAN communication (ECM) |
|
Communication with engine stop and start ECU continues for 2 seconds or more |
| U0129-87 | CAN communication (skid control ECU (brake actuator assembly)) |
|
Communication with engine stop and start ECU continues for 4.4 seconds or more |