Caution / Notice / Hint
The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during voltage inverter assembly removal/installation are shown below.
WARNING:
- Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair information.
Refer to PRECAUTION [11/2023 - ]
- To prevent electric shock, wear insulated gloves when working on wire harnesses and components of the high voltage system.
NOTE:
After the ignition switch is turned off, there may be a waiting time before disconnecting the negative (-) auxiliary battery terminal.
HINT:
When the cable is disconnected / reconnected to the auxiliary battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.
LEARNING COMPLETES WHEN VEHICLE IS DRIVEN
| Effect/Inoperative Function When Necessary Procedures are not Performed | Necessary Procedures | Link |
|---|---|---|
| Stop and Start System | Idle the engine for approximately 5 to 60 minutes or drive the vehicle until stop and start control is permitted | Refer to PRECAUTION [11/2023 - ] |
| Lane Control System | Perform steering sensor zero point calibration | Refer to INITIALIZATION [12/2019 - ] |
| Pre-collision System | ||
| Lighting System (EXT) (w/ AFS) |
LEARNING COMPLETES WHEN VEHICLE IS OPERATED NORMALLY
| Effect/Inoperative Function When Necessary Procedures are not Performed | Necessary Procedures | Link |
|---|---|---|
| Power Door Lock Control System | Initialize back door lock | Refer to INITIALIZATION [11/2023 - ] |
| Power Back Door System | Reset back door close position | Refer to INITIALIZATION [11/2023 - ] |
| Air Conditioning System | After the ignition switch is turned to ON, the servo motor standard position is recognized. | - |