Inspection [12/2019 - ]: Procedure
- INSPECT AC INVERTER RELAY
- Remove the AC INVERTER relay from the instrument panel junction block assembly.
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(AC INVERTER Relay)Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher 3 - 5 Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the AC INVERTER relay.
