Inspection [12/2019 - ]: Procedure
- INSPECT SEAT HEATER ASSEMBLY (for LH Side)
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Seat Heater Assembly (for LH Side))Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 Seat heater temperature 20 °C (68 °F) 3.36 to 4.02 Ω If the result is not as specified, replace the seat heater assembly (for LH side).
- Measure the resistance according to the value(s) in the table below.
- INSPECT SEAT HEATER ASSEMBLY (for RH Side)
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Seat Heater Assembly (for RH Side))Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 Seat heater temperature 20 °C (68 °F) 3.36 to 4.02 Ω If the result is not as specified, replace the seat heater assembly (for RH side).
- Measure the resistance according to the value(s) in the table below.