Inspection [12/2019 - ]: Procedure
- INSPECT SEAT HEATER ASSEMBLY (for LH Side)
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Seat Heater Assembly (for LH Side))Standard Resistance
Tester Connection Condition Specified Condition F5-1 - F5-4 Seat heater temperature 20 °C (68 °F) 3.19 to 3.83 Ω F5-1 - C-1 Seat heater temperature 20 °C (68 °F) Below 1 Ω F5-6 - F5-7 Seat heater temperature 20 °C (68 °F) 11.9 to 12.3 Ω F5-4 - C-2 Seat heater temperature 20 °C (68 °F) Below 1 Ω C-1 - C-2 Seat heater temperature 20 °C (68 °F) 3.26 to 3.90 Ω F5-3 - F5-4 Seat heater temperature 20 °C (68 °F) Below 1 Ω If the result is not as specified, replace the seat heater assembly (for LH side).
- Measure the resistance according to the value(s) in the table below.
- INSPECT SEAT HEATER ASSEMBLY (for RH Side)
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Seat Heater Assembly (for RH Side))Standard Resistance
Tester Connection Condition Specified Condition F1-1 - F1-4 Seat heater temperature 20 °C (68 °F) 3.19 to 3.83 Ω F1-1 - D-1 Seat heater temperature 20 °C (68 °F) Below 1 Ω F1-6 - F1-7 Seat heater temperature 20 °C (68 °F) 11.9 to 12.3 Ω F1-4 - D-2 Seat heater temperature 20 °C (68 °F) Below 1 Ω D-1 - D-2 Seat heater temperature 20 °C (68 °F) 3.26 to 3.90 Ω F1-3 - F1-4 Seat heater temperature 20 °C (68 °F) Below 1 Ω If the result is not as specified, replace the seat heater assembly (for RH side).
- Measure the resistance according to the value(s) in the table below.