Hazard Warning Switch Circuit [10/2022 - ]: Procedure
- READ VALUE USING GTS
- Read the Data List according to the display on the GTS.
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Hazard Flasher Switch Hazard warning signal switch signal OFF or ON OFF: Hazard warning signal switch off
ON: Hazard warning signal switch on- Body Electrical > Combination Meter > Data List
Tester Display Hazard Flasher Switch OK
Normal conditions listed above are displayed.
Result
Proceed to OK NG
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [10/2022 - 11/2023] , or refer to PROBLEM SYMPTOMS TABLE [11/2023 - ]
Result:
NG
See step 2
- Read the Data List according to the display on the GTS.
- INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY
Refer to INSPECTION [12/2019 - ]
Result
Proceed to OK NG Result:
NG
REPLACE HAZARD WARNING SIGNAL SWITCH ASSEMBLY. Refer to REMOVAL [10/2022 - ]
Result:
OK
See step 3
- CHECK HARNESS AND CONNECTOR (HAZARD WARNING SIGNAL SWITCH ASSEMBLY - COMBINATION METER ASSEMBLY AND BODY GROUND)
- Disconnect the H112 combination meter assembly connector. (for 12.3 Inch Display)
- Disconnect the H22 combination meter assembly connector. (except 12.3 Inch Display)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
FOR 12.3 INCH DISPLAYTester Connection Condition Specified Condition G6-6 (TB) - H112-12 (HAZ) Always Below 1 Ω G6-6 (TB) or H112-12 (HAZ) - Body ground Always 10 kΩ or higher G6-3 (E) - Body ground Always Below 1 Ω EXCEPT 12.3 INCH DISPLAYTester Connection Condition Specified Condition G6-6 (TB) - H22-3 (HAZ) Always Below 1 Ω G6-6 (TB) or H22-3 (HAZ) - Body ground Always 10 kΩ or higher G6-3 (E) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [12/2019 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR