DTC C1ABF-14: RCTA Buzzer Circuit Short to Ground or Open [11/2023 - ]: Procedure
- CHECK DTC
- Turn the ignition switch off.
- Turn the ignition switch to ON.
- Recheck for DTCs and check if the same DTC is output again.
Body Electrical > Blind Spot Monitor "A" > Trouble Codes
OK
No DTCs are output.
Result
Proceed to OK NG
Result:
OK
USE SIMULATION METHOD TO CHECK. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [12/2019 - ]
Result:
NG
See step 2
- CHECK HARNESS AND CONNECTOR (RCTA BUZZER (BLIND SPOT MONITOR BUZZER) - AUXILIARY BATTERY AND BLIND SPOT MONITOR SENSOR RH (A))
- Disconnect the M45 RCTA buzzer (blind spot monitor buzzer) connector.
- Disconnect the M2 blind spot monitor sensor RH (A) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition M45-2 (BZN) - M2-3 (BUZ) Always Below 1 Ω M45-2 (BZN) or M2-3 (BUZ) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 3
- REPLACE RCTA BUZZER (BLIND SPOT MONITOR BUZZER)
Refer to REMOVAL [12/2019 - ]
Result
Proceed to NEXT Result:
NEXT
See step 4
- CHECK DTC
- Clear the DTCs.
Body Electrical > Blind Spot Monitor "A" > Clear DTCs
- Recheck for DTCs and check if the same DTC is output again.
Body Electrical > Blind Spot Monitor "A" > Trouble Codes
OK
No DTCs are output.
Result
Proceed to OK NG
Result:
OK
END
Result:
NG
REPLACE BLIND SPOT MONITOR SENSOR RH (A). Refer to REMOVAL [11/2023 - ]
- Clear the DTCs.