Power Back Door does not Operate Using Outside Switch [12/2019 - 11/2023]: Procedure
- READ VALUE USING GTS
- Read the Data List according to the display on the GTS.
Body Electrical > Back Door > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note PBD Close SW No. 1 power back door control switch OFF or ON OFF: No. 1 power back door control switch not pressed
ON: No. 1 power back door control switch pressed- Body Electrical > Back Door > Data List
Tester Display PBD Close SW OK
The display is as specified in the normal condition column.
Result
Proceed to OK NG
Result:
OK
REPLACE MULTIPLEX NETWORK DOOR ECU. Refer to REMOVAL [12/2019 - 11/2023]
Result:
NG
See step 2
- Read the Data List according to the display on the GTS.
- INSPECT NO. 1 POWER BACK DOOR CONTROL SWITCH
Refer to INSPECTION [12/2019 - ]
Result
Proceed to OK NG Result:
NG
REPLACE NO. 1 POWER BACK DOOR CONTROL SWITCH. Refer to REMOVAL [12/2019 - ]
Result:
OK
See step 3
- CHECK HARNESS AND CONNECTOR (NO. 1 POWER BACK DOOR CONTROL SWITCH - MULTIPLEX NETWORK DOOR ECU AND BODY GROUND)
- Disconnect the W18 multiplex network door ECU connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition W17-5 (CLS) - W18-8 (BDDN) Always Below 1 Ω W17-2 (E) - Body ground Always Below 1 Ω W17-5 (CLS) or W18-8 (BDDN) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE MULTIPLEX NETWORK DOOR ECU. Refer to REMOVAL [12/2019 - 11/2023]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR