DTC B2251-01: Back Door Closer Switch General Electrical Failure [11/2023 - ]: Procedure
- READ VALUE USING GTS
- Read the Data List according to the display on the GTS.
Body Electrical > Back Door > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Half Latch Switch Latch switch signal ON or OFF OFF: Half latch position → full latch position - Body Electrical > Back Door > Data List
Tester Display Half Latch Switch Result
Result Proceed to The value of Half Latch Switch is OFF A None of the above conditions are met B
Result:
B
See step 7
Result:
A
See step 2
- Read the Data List according to the display on the GTS.
- READ VALUE USING GTS
- Read the Data List according to the display on the GTS.
Body Electrical > Back Door > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Half Latch Switch Latch switch signal ON or OFF ON: When in the open latch or overstroke position - Body Electrical > Back Door > Data List
Tester Display Half Latch Switch Result
Result Proceed to The value of Half Latch Switch is ON A None of the above conditions are met B
Result:
B
See step 7
Result:
A
See step 3
- Read the Data List according to the display on the GTS.
- READ VALUE USING GTS
- Read the Data List according to the display on the GTS.
Body Electrical > Back Door > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Pawl Switch Pawl switch signal ON or OFF OFF: Back door lock motor except open latched - Body Electrical > Back Door > Data List
Tester Display Pawl Switch Result
Result Proceed to The value of Pawl Switch is OFF A None of the above conditions are met B
Result:
B
See step 7
Result:
A
See step 4
- Read the Data List according to the display on the GTS.
- READ VALUE USING GTS
- Read the Data List according to the display on the GTS.
Body Electrical > Back Door > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Pawl Switch Pawl switch signal ON or OFF ON: Back door lock motor open-latched - Body Electrical > Back Door > Data List
Tester Display Pawl Switch Result
Result Proceed to The value of Pawl Switch is ON A None of the above conditions are met B
Result:
B
See step 7
Result:
A
See step 5
- Read the Data List according to the display on the GTS.
- READ VALUE USING GTS
- Read the Data List according to the display on the GTS.
Body Electrical > Back Door > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Courtesy Switch Back door courtesy switch signal ON or OFF OFF: Full latch position → overstroke position - Body Electrical > Back Door > Data List
Tester Display Courtesy Switch Result
Result Proceed to The value of Courtesy Switch is OFF A None of the above conditions are met B
Result:
B
See step 7
Result:
A
See step 6
- Read the Data List according to the display on the GTS.
- READ VALUE USING GTS
- Read the Data List according to the display on the GTS.
Body Electrical > Back Door > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Courtesy Switch Back door courtesy switch signal ON or OFF ON: Open latch position → half latch position - Body Electrical > Back Door > Data List
Tester Display Courtesy Switch Result
Result Proceed to The value of Courtesy Switch is ON A None of the above conditions are met B
Result:
A
REPLACE MULTIPLEX NETWORK DOOR ECU. Refer to REMOVAL [11/2023 - ]
Result:
B
See step 7
- Read the Data List according to the display on the GTS.
- INSPECT BACK DOOR LOCK WITH COURTESY LIGHT SWITCH ASSEMBLY
Refer to INSPECTION [12/2019 - ]
Result
Proceed to OK NG Result:
NG
REPLACE BACK DOOR LOCK WITH COURTESY LIGHT SWITCH ASSEMBLY. Refer to REMOVAL [12/2019 - ]
Result:
OK
See step 8
- CHECK HARNESS AND CONNECTOR (BACK DOOR LOCK WITH COURTESY LIGHT SWITCH ASSEMBLY - MULTIPLEX NETWORK DOOR ECU AND BODY GROUND)
Pre-procedure1
- Disconnect the W14 back door lock with courtesy light switch assembly connector.
- Disconnect the W30 multiplex network door ECU connector.
Procedure1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition W14-3 (CLS) - W30-5 (HAF) Always Below 1 Ω W14-2 (FSW) - W30-13 (PAWL) Always Below 1 Ω W14-4 (CTY) - W30-3 (FUL) Always Below 1 Ω W14-1 (E) - Body ground Always Below 1 Ω W14-3 (CLS) or W30-5 (HAF) - Body ground Always 10 kΩ or higher W14-2 (FSW) or W30-13 (PAWL) - Body ground Always 10 kΩ or higher W14-4 (CTY) or W30-3 (FUL) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG Post-procedure1
- None
Result:
OK
REPLACE MULTIPLEX NETWORK DOOR ECU. Refer to REMOVAL [11/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR